• Reg Anesth Pain Med · Jan 1999

    Multicenter Study Clinical Trial

    The PENCAN 25-gauge needle: a new pencil-point needle for spinal anesthesia tested in 1,193 patients.

    • E J Krommendijk, R Verheijen, B van Dijk, E M Spoelder, M J Gielen, and J J de Lange.
    • Department of Anesthesiology, Vrije Universiteit, Amsterdam, The Netherlands.
    • Reg Anesth Pain Med. 1999 Jan 1; 24 (1): 43-50.

    Background And ObjectivesThe PENCAN 25-gauge spinal needle is a new pencil-point needle with an inner diameter of 0.32 mm resulting in a relatively high cerebrospinal fluid (CSF) flow. The PENCAN 25-gauge needle was tested for ease of identification of a successful dural puncture, the failure rate of spinal anesthesia, and the incidence of postdural puncture headache (PDPH).MethodsIn a multicenter trial, the needle was tested in patients undergoing spinal anesthesia. A questionnaire evaluated the characteristics of the dural puncture. A second questionnaire was used to assess postspinal side effects (PDPH, atypical headache, audiovisual disturbances).ResultsIn 1,193 patients, dural puncture was evaluated as easy in 85.2%, as moderate in 6.2%, as difficult in 6.7%, and as impossible in 1.9%. Needle performance was assessed as excellent or satisfactory in 96.9%. In 95.9% of patients, CSF appeared within 2 seconds. A perceptible "click" was noticed in 78.4% of patients. In 1.9%, CSF could not be obtained, because of spine deformities, obesity, or bending of the needle. In 1,166 patients, postpuncture complaints were evaluated, involving 635 women (54.5%), 773 patients (66.3%) under the age of 50 years old, and 170 (14.6%) cesarean deliveries. The overall incidence of PDPH was 1.3% (n = 15). A bloodpatch was needed in five patients. After cesarean delivery the incidence of PDPH was 3.4%, all responding to conservative treatment. Atypical headache and isolated audiovisual disturbances occurred in 7.5% and 1.5% of patients, respectively.ConclusionsA failure rate of 1.9% together with a 1.3% incidence of PDPH were comparable to other 25-gauge pencil-point needles. The rapid appearance of CSF and a perceptible "click" made prompt recognition of successful dural puncture possible.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.