• J Emerg Nurs · Sep 2016

    First or Second Drop of Blood in Capillary Glucose Monitoring: Findings from a Quantitative Study.

    • Alvisa Palese, Elisa Fabbro, Anica Casetta, and Irene Mansutti.
    • Udine, Italy. Electronic address: alvisa.palese@uniud.it.
    • J Emerg Nurs. 2016 Sep 1; 42 (5): 420-6.

    UnlabelledFor clinical nurses, especially those working in emergency departments, it is crucial to measure blood glucose (BG) in an accurate, timely, and safe manner. Many differences in practice exist with regard to use of the first or second drop of blood for testing, and no consistent guidelines are available for capillary BG testing at home or in ED settings. The purpose of this study is to evaluate the BG differences between the first and second drop of capillary blood collected from the same site in patients with type 1 diabetes.MethodsA consecutive sample of 195 persons with type 1 diabetes who had washed their hands and were not suspected of having hypoglycemia were included in the study. Descriptive and inferential statistical analysis for non-normal distributed variables was performed.ResultsA strong correlation emerged between the BG reported in the first and the second drops (Spearman's rho test [rs] 0.979, P < .001; Pearson r 0.978, P < .001). The average BG values obtained from the first and second drops were 184.30 mg/dL (median, 166) and 187.6 mg/dL (median, 172), respectively, and thus the second drop showed higher glucose values compared with the first drop. However, BG values of the second drop were not higher in all occasions: whereas some evaluations reported higher BG values in the second drop capillary sample (n = 123), others reported higher values in the first drop (n = 65), and still others reported identical measurements in the first and second drops (n = 7). Five outliers were present with a BG difference from -39 to -53 mg/dL in the first drop compared with the second drop, and 3 outliers were present with a BG difference from +46 to +57 mg/dL in the first drop compared with the second drop. However, the differences that emerged were not affected by glucose concentration (P = .221).DiscussionUsing the first drop of blood in a patient with clean hands allows emergency nurses to perform the test more quickly, resulting in immediate information. Findings indicate that the first drop of blood is adequate for clinical decision making, but the clinician should use judgment if using protocols in which small values (eg, 6 mg/dL) are important, because the first drop is more likely to have a slightly lower value.Copyright © 2016 Emergency Nurses Association. Published by Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.