• Am. J. Crit. Care · Mar 2015

    Observational Study

    Pleth variability index and fluid responsiveness of hemodynamically stable patients after cardiothoracic surgery.

    • Brandon C Maughan, Todd A Seigel, and Anthony M Napoli.
    • When this study was done, all authors were affiliated with the Department of Emergency Medicine, Alpert Medical School of Brown University/Rhode Island Hospital, Providence, Rhode Island. Brandon C. Maughan is now a Robert Wood Johnson Clinical Scholar at the Philadelphia Veterans Affairs Medical Center and the University of Pennsylvania, and a fellow at the Leonard Davis Institute of Health Economics at the University of Pennsylvania in Philadelphia. Todd A. Seigel is now an associate physician in the Departments of Emergency Medicine and Critical Care at Kaiser Oakland Medical Center, Oakland, California. Anthony M. Napoli is an associate professor of emergency medicine at the Alpert Medical School of Brown University/Rhode Island Hospital. Brandon.Maughan@uphs.upenn.edu.
    • Am. J. Crit. Care. 2015 Mar 1;24(2):172-5.

    BackgroundFluid responsiveness is a measure of preload dependence and is defined as an increase in cardiac output due to volume expansion. Recent publications have suggested that variation in amplitude of the pulse oximetry waveform may be predictive of fluid responsiveness. The pleth variability index (PVI) was developed as a noninvasive bedside measurement of this variation in the pulse oximetry waveform.ObjectivesTo measure the discriminatory value of PVI for predicting fluid responsiveness as measured by pulmonary artery catheter thermodilution in patients after cardiothoracic surgery.MethodsA prospective observational study of hemodynamically stable postoperative cardiac surgery patients with pulmonary artery catheters. A fingertip sensor was used to measure PVI. Vital signs, PVI, and cardiac index were measured before, during, and after passive leg raise. Fluid responsiveness was defined by increase in cardiac index of greater than 15% during passive leg raise. The discriminatory value of PVI was assessed by using the Wilcoxon method to measure the area under the receiver operating curve.ResultsIn 13 months, 47 patients (24 receiving mechanical ventilation, 23 spontaneously breathing) were enrolled. Fluid responsiveness was noted in 42% of intubated patients and 48% of spontaneously breathing patients. PVI was not adequate to discriminate fluid responsiveness in intubated patients (area under curve, 0.63; P = .16) or spontaneously breathing patients (area under curve, 0.41; P = .75).ConclusionsAmong postoperative cardiac surgery patients, PVI is not reliable for predicting fluid responsiveness as measured by pulmonary artery catheter thermodilution, regardless of ventilatory status.©2015 American Association of Critical-Care Nurses.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…