• Int J Cardiovasc Imaging · Apr 2011

    Occlusion of Fontan fenestrations using Amplatzer septal occluder.

    • Amira A A H Al-Hay, Lulu Abu Shaban, Mustafa A Al-Qbandi, Muath Alanbaei, and Muath Al Anbaei.
    • Departments of Pediatric Cardiology, Chest Diseases Hospital, PO Box 4278, Salmia, 22043 Kuwait. amira_alhay@hotmail.com
    • Int J Cardiovasc Imaging. 2011 Apr 1; 27 (4): 483-90.

    AbstractThe objective of the study is to assess efficacy and safety of the Amplatzer septal device for percutaneous occlusion of Fontan fenestration. Fenestration improves postoperative outcomes in children undergoing Fontan repair. Many of these fenestrations close spontaneously; persistent fenestrations ultimately cause desaturation and can be a potential cause of paradoxical embolism. This is a retrospective review of 26 consecutive patients who underwent transcatheter closure of Fontan fenestration in a tertiary cardiac center in Kuwait. After assessment of hemodynamic suitability for fenestration closure, appropriate balloon sizing of fenestration was obtained. The median age was 9.2 years (range = 1.5-18.3 years). Occlusion was accomplished using a 4-7 ml single Amplatzer septal device in 12 patients and 8-13 ml devices in the other 13 patients; 2 devices were deployed in one patient. Median fluoroscopic and procedure times were 22 and 143.5 min, respectively. One immediate complication was the embolization and successful retrieval of the Amplatzer duct occluder. The fenestration was subsequently occluded by Amplatzer septal device. A 100% occlusion rate of fenestration was achieved in both lateral tunnel and extracardiac conduit types of Fontans. Mean (SD) arterial oxygen saturation increased from 84.7% (4.7) to 95.2% (1.7, P < 0.001) 10 min after deployment of the occluder; Fontan mean circuit pressure had a minimal acceptable increment from 12.9 mmHg (3.2) to 14.6 mmHg (2.6, P < 0.001). No complications or device failures were seen during follow up. The Amplatzer septal occluder device is effective in closing both Fontan fenestrations. Longer single or dual anti-platelet therapy may be considered to prevent thrombotic events. Long-term outpatients follow up with transthoracic echocardiographic monitoring for systemic venous congestion or thrombosis is warranted.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…