• J. Cardiothorac. Vasc. Anesth. · Aug 2015

    Review Meta Analysis Comparative Study

    A Comparison of the Efficacy and Adverse Effects of Double-Lumen Endobronchial Tubes and Bronchial Blockers in Thoracic Surgery: A Systematic Review and Meta-analysis of Randomized Controlled Trials.

    • Ana Clayton-Smith, Kyle Bennett, Robin Peter Alston, George Adams, Greg Brown, Timothy Hawthorne, May Hu, Angus Sinclair, and Jay Tan.
    • College of Medicine and Veterinary Medicine, Academic Administration, The University of Edinburgh, Edinburgh, United Kingdom. Electronic address: s1202024@sms.ed.ac.uk.
    • J. Cardiothorac. Vasc. Anesth. 2015 Aug 1; 29 (4): 955-66.

    ObjectiveTo compare the efficacy and adverse effects of using bronchial blockers (BBs) and double-lumen endobronchial tubes (DLTs).DesignSystematic review and meta-analysis of randomized controlled trials (RCTs) comparing BBs and DLTs.SettingHospital units undertaking thoracic surgeryParticipantsPatients undergoing thoracic surgery requiring lung isolation.InterventionsBBs and DLTs.Measurements And Main ResultsA systematic literature search was conducted for RCTs comparing BBs and DLTs using Google Scholar, Ovid Medline, and Cochrane library databases up to October 2013. Inclusion criteria were RCTs comparing BBs and DLTs, intubation carried out by qualified anesthesiologists or trainee specialists, outcome measures relating to either efficacy or adverse effects. Studies that were inaccessible in English were excluded. Mantel-Haenszel fixed-effect meta-analysis of recurring outcome measures was performed using RevMan 5 software. The search produced 39 RCTs published between 1996 and 2013. DLTs were quicker to place (mean difference: 51 seconds, 95% confidence intervals [CI] 8-94 seconds; p = 0.02) and less likely to be incorrectly positioned (odds ratio [OR] 2.70; 95% CI 1.18-6.18, p = 0.02) than BBs. BBs were associated with fewer patients having a postoperative sore throat (OR 0.39, 95% CI: 0.23-0.68, p = 0.0009), less hoarseness (OR: 0.43,95%, CI 0.24-0.75, p = 0.003), and fewer airway injuries (OR 0.40, 95% CI 0.21-0.75, p = 0.005) than DLTs.ConclusionWhile BBs are associated with a lower incidence of airway injury and a lower severity of injury, DLTs can be placed quicker and more reliably.Copyright © 2015 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.