• J Clin Monit · Apr 1990

    Frequently repeated Fick cardiac output measurements during anesthesia.

    • M Doi, K Morita, and K Ikeda.
    • Department of Anesthesiology, Hamamatsu University School of Medicine, Shizuoka, Japan.
    • J Clin Monit. 1990 Apr 1; 6 (2): 107-12.

    AbstractA computer-based system was developed for monitoring cardiac output using the Fick principle during general anesthesia. The variables of the oxygen-consumption Fick equation were measured using the following system: oxygen uptake by an originally developed respiratory gas monitoring system, arteriovenous oxygen saturation difference by pulse and fiberoptic oximetry, and hemoglobin concentration by an in vitro oximeter. Fick cardiac output and systemic vascular resistance were calculated every 30 seconds. Fick cardiac output was compared with thermodilution cardiac output in 11 anesthetized patients. A total of 208 corresponding cardiac output measurements showed a range of 2 to 9 L.min-1. The correlation coefficient between the thermodilution and Fick cardiac outputs was 0.961, with a regression equation of Fick cardiac output = 1.058 thermodilution cardiac output - 0.359. The difference between the thermodilution and Fick cardiac outputs was 0.103 +/- 0.395. The Fick cardiac output was significantly lower than the thermodilution cardiac output, especially in the low flow range. We demonstrated that this new monitoring system was clinically feasible and sufficiently accurate, under the limited circumstances of our study. The integration of routinely used equipment has made possible a frequently repeatable method for estimating cardiac output in patients.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…