J. Cardiovasc. Electrophysiol. · Sep 2003
Randomized Controlled Trial Clinical TrialAnalysis of implantable cardioverter defibrillator therapy in the Antiarrhythmics Versus Implantable Defibrillators (AVID) Trial.
- Richard C Klein, Merritt H Raitt, Bruce L Wilkoff, Karen J Beckman, James Coromilas, D George Wyse, Peter L Friedman, James B Martins, Andrew E Epstein, Alfred P Hallstrom, Robert B Ledingham, Karen M Belco, H Leon Greene, and AVID Investigators.
- Cardiology Division, University of Utah Health Sciences Center and VA Medical Center, 50 N. Medical Drive, Salt Lake City, UT 84132, USA. richard.klein@hsc.utah.edu
- J. Cardiovasc. Electrophysiol. 2003 Sep 1; 14 (9): 940-8.
IntroductionThe implantable cardioverter defibrillator (ICD) is commonly used to treat patients with documented sustained ventricular tachycardia (VT) or ventricular fibrillation (VF). Arrhythmia recurrence rates in these patients are high, but which patients will receive a therapy and the forms of arrhythmia recurrence (VT or VF) are poorly understood.Methods And ResultsThe therapy delivered by the ICD was examined in 449 patients randomized to ICD therapy in the Antiarrhythmics Versus Implantable Defibrillators (AVID) Trial. Events triggering ICD shocks or antitachycardia pacing (ATP) were reviewed for arrhythmia diagnosis, clinical symptoms, activity at the onset of the arrhythmia, and appropriateness and results of therapy. Both shock and ATP therapies were frequent by 2 years, with 68% of patients receiving some therapy or having an arrhythmic death. An appropriate shock was delivered in 53% of patients, and ATP was delivered in 68% of patients who had ATP activated. The first arrhythmia treated in follow-up was diagnosed as VT (63%), VF (13%), supraventricular tachycardia (18%), unknown arrhythmia (3%), or due to ICD malfunction or inappropriate sensing (3%). Acceleration of an arrhythmia by the ICD occurred in 8% of patients who received any therapy. No physical activity consistently preceded arrhythmias, nor did any single clinical factor predict the symptoms of the arrhythmia.ConclusionDelivery of ICD therapy in AVID patients was common, primarily due to VT. Inappropriate ICD therapy occurred frequently. Use of ICD therapy as a surrogate endpoint for death in clinical trials should be avoided.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.