• Der Anaesthesist · Apr 2015

    Randomized Controlled Trial Comparative Study

    Randomized comparison of the i-gel(TM) with the LMA Supreme (TM) in anesthetized adult patients.

    • J M Beleña, M Núñez, A Vidal, C Gasco, A Alcojor, P Lee, and J L Pérez.
    • Department of Anesthesiology and Critical Care, Sureste University Hospital, 28500, C/Ronda del Sur, 10, Arganda del Rey, Madrid, Spain, josemariabelena@yahoo.es.
    • Anaesthesist. 2015 Apr 1;64(4):271-6.

    BackgroundThe LMA Supreme(TM) (LMA-S) and i-gel(TM) are two of the most commonly used supraglottic airway devices (SADs) with an inbuilt drain channel. These devices are particularly indicated for performing certain procedures accompanied by high peak airway pressure, such as laparoscopy. This study compared the devices regarding efficacy, safety, ease of use and incidence of adverse events, focusing on the postoperative rate of sore throat, dysphagia or dysphonia and development with time, in patients undergoing laparoscopic cholecystectomy procedures under general anesthesia.MethodsThis was a prospective, randomized, controlled clinical study including 140 patients randomized into 2 groups undergoing elective laparoscopic cholecystectomy to use either i-gel or LMA-S. After the general anesthesia procedure, the speed of insertion, success rates, ease of insertion of the drain tube, leak pressure and tidal volume achieved by the devices were evaluated. The postoperative oropharyngeal discomfort (POPD) during the period of stay of the patients in the recovery room was also recorded.ResultsThe mean leak pressure was comparable between the two groups (i-gel 28.18 ± 3.90 cmH2O and LMA-S 27.50 ± 4 cmH2O, p = 0.09), as well as maximum expiratory tidal volume provided (i-gel 559.60 ± 45.25 ml and LMA-S 548.95 ± 56.18 ml, p = 0.12). Insertion times were lower for the i-gel (10 ± 1.62 s) compared with the LMA-S (11.31 ± 2.85 s, p = 0.008). Insertion success rate at the first attempt was higher for the LMA-S (95 % compared with i-gel 79 %, p = 0.007). Drain tubes were easier to insert in the LMA-S group (p < 0.001). No differences were found between groups relating to intraoperative complications. Frequency of coughing and visible blood on removal of the device were low and comparable in both groups (p = 0.860 and p = 0.623, respectively). There were no differences relating to the incidence of sore throat, dysphagia or hoarseness at 10 min postoperatively between groups (p = 0.088). The i-gel group complained about a higher sore throat score at 2 h postoperatively (p = 0.009), specifically patients receiving i-gel suffered more from sore throats with 0.24 more points on the visual analog scale (VAS) than patients from the LMA-S group. The i-gel group also reported a lower POPD drop during the first 2 h (p < 0.001).ConclusionNo differences were found between i-gel and LMA-S regarding leak pressure in the groups of anesthetized patients undergoing laparoscopic cholecystectomy. The LMA-S was easier to insert than the i-gel (based on its better first time success rate) and this device showed better ease of drain tube insertion, although the i-gel was quicker to insert than the LMA-S. The i-gel resulted in higher sore throat scores at 2 h postoperatively and lower POPD reduction during the 2 h period studied in the recovery room was reported.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.