Randomized Controlled Trial
Performance of intubation with 4 different airway devices by unskilled rescuers: manikin study.
- Dong Woo Lee, Mun Ju Kang, Yong Hwan Kim, Jun Ho Lee, Kwang Won Cho, Yang Weon Kim, Jun Hwi Cho, Young Sik Kim, Chong Kun Hong, and Seong Youn Hwang.
- Department of Emergency Medicine, Samsung Changwon Hospital, Sungkyunkwan University School of Medicine, Changwon, Republic of Korea.
- Am J Emerg Med. 2015 May 1;33(5):691-6.
IntroductionThis study was designed to compare the performances of 4 airway devices in achieving successful ventilation.MethodsA randomized crossover trial was conducted to evaluate 4 airway devices: laryngeal mask airway (LMA), i-gel (iGEL), PENTAX Airway Scope (AWS), and Macintosh laryngoscope (MCL). Thirty-eight unskilled rescuers performed intubation on a manikin during chest compressions in normal and difficult airway scenarios. The time to ventilation, intubation success rate, and difficulty of intubation were measured.ResultsThe time to ventilation of the airway devices in the normal scenario had a median value of 8.8 seconds (interquartile range, 7.3-10.5 seconds) for iGEL, 16.1 seconds (13.9-19.3 seconds) for LMA, 30.6 seconds (24.6-37.6 seconds) for AWS, and 35.0 seconds (29.5-45.9 seconds) for MCL. In the difficult airway scenario, the respective time to ventilation was 8.6 seconds (7.8-10.0 seconds), 15.3 seconds (14.3-20.2 seconds), 29.4 seconds (25.7-36.3 seconds) and 59.0 seconds (46.1-103.3 seconds). The success rates were 100% and 100% for LMA, 100% and 100% for iGEL, 97.4% and 94.7% for AWS, and 78.9% and 47.4% for MCL in the normal and difficult airway scenarios. The difficulties of intubation expressed as numerical rating scale were 2.0 and 2.0 (median values) for LMA, 1.0 and 2.0 for iGEL, 3.0 and 3.0 for AWS, and 4.0 and 5.0 for MCL in the normal and difficult airway scenarios, respectively.ConclusionWith novice intubators who were unfamiliar with the airway devices, the LMA, iGEL, and AWS were superior to the MCL for establishing an airway without interruption of chest compressions in a manikin study. Intubation with the iGEL was faster and easier than with the other airway devices.Copyright © 2015 Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.