• Neurosurg Focus · Jan 2001

    Comparative Study Clinical Trial

    The Zeiss-MKM system for frameless image-guided approach in epidural motor cortex stimulation for central neuropathic pain.

    • B Pirotte, P Voordecker, F Joffroy, N Massager, D Wikler, D Baleriaux, M Levivier, and J Brotchi.
    • Department of Neurosurgery, Erasme Hospital, University of Brussels, Belgium. bpirotte@ulb.ac.be
    • Neurosurg Focus. 2001 Jan 1; 11 (3): E3.

    ObjectTwelve patients (seven female, and five male, mean age 55.6 years) suffering from refractory central (ischemic/traumatic [eight cases]) and neuropathic pain (trigeminal neuropathy [four cases]) underwent surgery for the implantation of an epidural motor cortex stimulation (MCS) device in which the authors used a frameless neuronavigation system, the Zeiss-MKM microscope.MethodsThe authors assessed the spatial accuracy of the neuronavigation system and its potential contribution to improve the quality of targeting pain. In these patients, the positions of the central sulcus, defined by stereotactic magnetic resonance MR imaging, intraoperative somatosensory evoked potentials (SSEPs) and subdural visual verification, were correlated into the stereotactic neuronavigation planning procedure. The mean spatial accuracy of distance between (MR) imaging-defined and actual central sulcus was 2.4 mm (range 5-10 mm). The intraoperative SSEPdefined central sulcus was close to that defined by MR imaging (mean distance 6.4 mm). Although very precise, intraoperative SSEP recordings were impaired by artifacts and wave attenuation in six of the 12 patients. Stereotactic correlations between anatomical and functional data in the navigation system corrected final targeting in 10 of 12 cases. Pain relief was obtained in eight patients. Indeed, inappropriate targeting probably explains the reported variable success rate of MCS and certainly underestimates the actual efficacy.ConclusionsSince intraoperative SSEP monitoring has, for many years, been considered the standard procedure to approach motor target, the development of an accurate stereotactic image guidance system could help to increase the efficacy of MCS on the alleviation of pain. The excellent spatial accuracy provided by the Zeiss-MKM navigation system allows precise data correlations that represent a remarkable means to validate functional MR imaging as an alternative to SSEP. The authors believe that developing stereotactic image guidance with such a navigation system could improve the success rate of MCS.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…