-
IEEE Trans Biomed Eng · Sep 2013
Intensity-modulated microbend fiber optic sensor for respiratory monitoring and gating during MRI.
- Doreen Lau, Zhihao Chen, Ju Teng Teo, Soon Huat Ng, Helmut Rumpel, Yong Lian, Hui Yang, and Pin Lin Kei.
- Department of Diagnostic Radiology, Singapore General Hospital, Singapore. doreen.lau.a.h@sgh.com.sg
- IEEE Trans Biomed Eng. 2013 Sep 1; 60 (9): 2655-62.
AbstractThis paper describes a novel microbend fiber optic sensor system for respiratory monitoring and respiratory gating in the MRI environment. The system enables the noninvasive real-time monitoring and measurement of breathing rate and respiratory/body movement pattern of healthy subjects inside the MRI gantry, and has potential application in respiratory-gated image acquisition based on respiratory cues. The working principle behind this sensor is based on the microbending effect of an optical fiber on light transmission. The sensor system comprises of a 1.0-mm-thin graded-index multimode optical fiber-embedded plastic sensor mat, a photoelectronic transceiver, and a computer with a digital signal processing algorithm. In vitro testing showed that our sensor has a typical signal-to-noise ratio better than 28 dB. Clinical MRI trials conducted on 20 healthy human subjects showed good and comparable breathing rate detection (with an accuracy of ±2 bpm) and respiratory-gated image quality produced using the sensor system, with reference to current predicate hospital device/system. The MRI safe, ease of operation characteristics, low fabrication cost, and extra patient comfort offered by this system suggest its good potential in replacing predicate device/system and serve as a dual function in real-time respiratory monitoring and respiratory-gated image acquisition at the same time during MRI.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.