• J Arthroplasty · Sep 2016

    Intraoperative Adductor Canal Block for Augmentation of Periarticular Injection in Total Knee Arthroplasty: A Cadaveric Study.

    • Andrew M Pepper, Trevor W North, Adam M Sunderland, and Jason J Davis.
    • Department of Orthopaedic Surgery, Henry Ford Health System, Detroit, Michigan.
    • J Arthroplasty. 2016 Sep 1; 31 (9): 2072-6.

    BackgroundFunction is often sacrificed for pain control after total knee arthroplasty. Motor-sparing blocks, including adductor canal block (ACB) and periarticular injection (PAI), have gained interest to address this compromise. Our study evaluates the anatomic feasibility, accuracy, and safety of intraoperative ACB as an adjunct to PAI by analyzing 3 different injection orientations and needle configurations.MethodsEleven cadaveric knees underwent a standard medial parapatellar arthrotomy. Blunt dissection through the suprapatellar recess was performed. Using a 10-mL syringe, various colors of dyed liquid gelatin were injected toward the proximal and distal adductor canal (AC) using 3 needle configurations. Medial dissection of the knee for each specimen was performed. The position of each needle and location of injected dye was identified and described relative to the AC.ResultsAccuracy of each injection orientation and/or needle configuration was different: 86% for a blunt needle in the distal AC, 57% for blunt needle in the proximal AC, and 14% for a spinal needle in the proximal AC. Puncture of the femoral artery was observed with the spinal needle 43% of the time and had the closest average proximity to the femoral artery with a distance of 5.9 mm. There were no vascular punctures using blunt needles, and the average distance from the femoral artery with proximal and distal orientation was 10.2 mm and 15.4 mm, respectively.ConclusionIntraoperative ACB augmentation of PAI appears to be anatomically feasible and safe. There was decreased accuracy and increased risk of vascular puncture using a 3.5-inch spinal needle. A blunt 1.5-inch needle directed toward the distal AC had the highest accuracy while minimizing vascular injury.Copyright © 2016 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…