-
Comparative Study
Measurements of PEEP-induced changes in lung volume: evaluation of a laser monitor.
- T Uhlig, T Kondo, and P D Sly.
- Division of Clinical Sciences, TVW Telethon Institute for Child Health Research, West Perth, Australia.
- Chest. 1997 Jul 1; 112 (1): 107-12.
Study ObjectiveTo evaluate a newly developed laser monitor in the measurement of positive end-expiratory pressure (PEEP)-induced changes in end-expiratory lung volume (EELV) in spontaneously breathing subjects.DesignAn open comparison between two different methods to assess breathing parameters.SettingA respiratory research unit.ParticipantsSix spontaneously breathing, healthy volunteers.InterventionsStepwise increases of PEEP from 0 to 0.8 to 1.6 kPa during spontaneous breathing; repeated validation of the laser monitor in each subject.Measurements And ResultsPressure and flow were recorded at the airway opening. Abdominal wall displacement (AWD) measured by the laser sensor was recorded simultaneously. The time lag between the volume and the laser signals during baseline was 0.068+/-0.052 s and during maximal PEEP, 0.108+/-0.093 s. There was no baseline drift in either the PEEP or the AWD signals. Mean EELV decreased by 290 mL to 1,157 mL after the PEEP valve was removed. Within each individual, the ratio between EELV and AWD showed only small variations. Measurements of tidal volume (VT) and AWD showed good agreement at all PEEP levels. Mean VT decreased in all but one subject during PEEP. With the increase in PEEP, the end-expiratory abdominal baseline increased linearly over a large range of end-expiratory pressures with a flattening of the curve at high PEEP levels in all subjects.ConclusionsThe laser monitor is sufficiently accurate for measuring PEEP-induced changes in EELV during spontaneous breathing in healthy adult subjects. Monitors incorporating multiple laser sensors may have considerable clinical promise.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.