Comparative Study
The BioSTAR(r) device versus the CardioSEAL(r) device in patent foramen ovale closure: comparison of mid-term efficacy and safety.
- Ben J Van den Branden, Justin G Luermans, Martijn C Post, Herbert W Plokker, Jurriën M Ten Berg, and Maarten J Suttorp.
- Department of Interventional Cardiology, St. Antonius Hospital, Nieuwegein, The Netherlands. b.van.den.branden@antoniusziekenhuis.nl
- EuroIntervention. 2010 Sep 1; 6 (4): 498-504.
AimsTo compare the mid-term efficacy and safety of the bioabsorbable BioSTAR(r) device with the non-bioabsorbable CardioSEAL(r) device for percutaneous patent foramen ovale (PFO) closure.Methods And ResultsAll 81 consecutive patients who underwent PFO closure with the CardioSEAL(r) or BioSTAR(r) device between June 2003 and July 2008 were included. The presence of a residual shunt (minimal, moderate or large) was measured in both groups at six months follow-up, using contrast transthoracic echocardiography. Forty-four patients (48.4±11.4 years) received the CardioSEAL(r) device and 37 patients the BioSTAR(r) device (47.9±10.7 years). There were no significant differences in short-term complications. Two patients who received the BioSTAR(r) device developed a recurrent transient cerebral ischaemic event. Overall, atrial arrhythmias occurred in 19%, with no difference between both groups. At six months, a residual shunt was present in 29% (27% minimal, 2% moderate) using the CardioSEAL(r) device compared to 28% (17% minimal, 11% moderate) using the BioSTAR(r) device (p=0.18). A predictor for residual shunt could not be found.ConclusionsThere is no difference in safety and efficacy at six months between the CardioSEAL(r) and BioSTAR(r) device used for PFO closure. However, using the BioSTAR(r) device tends to be associated with a higher percentage of moderate shunting.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.