-
Respir Physiol Neurobiol · Feb 2014
An open-source software for automatic calculation of respiratory parameters based on esophageal pressure.
- Louis Mayaud, Michèle Lejaille, Hélène Prigent, Bruno Louis, Brigitte Fauroux, and Frédéric Lofaso.
- INSERM, Centre d'Investigation Clinique et d'Innovation technologique (CICIT), UMR805, Garches, France; EA4497, Université Versailles Saint-Quentin (UVSQ), Versailles, France; Hôpital Raymond Poincaré, APHP, Garches, France; Institute of Biomedical Engineering (IBME), University of Oxford, Oxford, UK. Electronic address: louis.mayaud@gmail.com.
- Respir Physiol Neurobiol. 2014 Feb 1; 192: 1-6.
PurposeWe have developed a software that automatically calculates respiratory effort indices, including intrinsic end expiratory pressure (PEEPi) and esophageal pressure-time product (PTPeso).Materials And MethodsThe software first identifies respiratory periods. Clean signals are averaged to provide a reference mean cycle from which respiratory parameters are extracted. The onset of the inspiratory effort is detected automatically by looking backward from the onset of inspiratory flow to the first point where the esophageal pressure derivative is equal to zero (inflection point). PEEPi is derived from this point. Twenty-three recordings from 16 patients were analyzed with the algorithm and compared with experts' manual analysis of signals: 15 recordings were performed during spontaneous breathing, 1 during non-invasive mechanical ventilation, and 7 under both conditions.ResultsFor all values, the coefficients of determinations (r(2)) exceeded 0.94 (p<0.001). The bias (mean difference) between PEEPi calculated by hand and automatically was -0.26±0.52cmH2O during spontaneous breathing and the precisions (standard deviations of the differences) was 0.52cmH2O with limits of agreement of 0.78 and -1.30cmH2O. The mean difference between PTPeso calculated by hand and automatically was -0.38±1.42cmH2Os/cycle with limits of agreement of 2.46 and -3.22cmH2Os/cycle.ConclusionsOur program provides a reliable method for the automatic calculation of PEEPi and respiratory effort indices, which may facilitate the use of these variables in clinical practice. The software is open source and can be improved with the development and validation of new respiratory parameters.Copyright © 2013 Elsevier B.V. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.