• J Bone Joint Surg Am · Apr 2013

    Center and surgeon volume influence the revision rate following unicondylar knee replacement: an analysis of 23,400 medial cemented unicondylar knee replacements.

    • Paul Baker, Simon Jameson, Rebecca Critchley, Mike Reed, Paul Gregg, and David Deehan.
    • Institute of Cellular Medicine, Newcastle University, Framlington Place, Newcastle upon Tyne, England. drpnbaker@hotmail.com
    • J Bone Joint Surg Am. 2013 Apr 17; 95 (8): 702-9.

    BackgroundRevision rates following unicondylar knee replacement vary among reporting institutions. Revision rates from institutions involved in the design of these implants and independent single-center series are comparable with those following total knee replacement, suggesting that higher operative volumes and surgical enthusiasm improve revision outcomes.MethodsThis registry-based cohort study involved the analysis of 23,400 medial cemented Oxford unicondylar knee replacements for the treatment of osteoarthritis. Total center and surgeon operative volumes were calculated over an eight-year time span since the inception of the registry (April 2003 to December 2010). The revision rate was calculated according to center volume and surgeon volume, each of which was grouped into five categories. The groups were compared with use of life tables, Kaplan-Meier plots, and Cox regression models that adjusted for variations in age, sex, and American Society of Anesthesiologists (ASA) grade among the groups.ResultsA total of 919 surgeons and a total of 366 centers performed at least one replacement, with the majority performing a small number of procedures. The revision rate for the centers with the lowest volume (fifty or fewer procedures over the eight-year study period) was 1.62 (95% confidence interval [CI], 1.42 to 1.82) revisions per 100 component years; this was significantly higher than the rate for the centers with the highest volume (more than 400 procedures), which was 1.16 (95% CI, 0.97 to 1.36) revisions per 100 component years. The five-year implant survival rate of 92.3% (95% CI, 91.2% to 93.3%) for the lowest-volume centers was significantly lower than the rate of 94.1% (95% CI, 93.0% to 95.2%) for the highest-volume centers. Similarly, the revision rate for the surgeons with the lowest volume (twenty-five or fewer procedures), 2.16 (95% CI, 1.91 to 2.41) revisions per 100 component years, was significantly higher than that for the surgeons with the highest volume (more than 200 procedures), 0.80 (95% CI, 0.62 to 0.98) revisions per 100 component years. The five-year survival rate of 90.1% (95% CI, 88.8% to 91.3%) for the lowest-volume surgeons was also significantly lower than the rate of 96.0% (95% CI, 95.0% to 97.0%) for the highest-volume surgeons. When center and surgeon volume were considered simultaneously, the hazard of revision was greater for lower-volume surgeons at lower-volume centers compared with higher-volume surgeons at higher-volume centers (hazard ratio = 1.87 [95% CI, 1.58 to 2.22], p < 0.001).ConclusionsHigh-volume centers and surgeons specializing in such procedures had superior results following unicondylar knee replacement compared with their low-volume counterparts. These results suggest that centers and surgeons should undertake a minimum of thirteen such procedures per year to achieve results comparable with the high-volume operators.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…