-
J. Thromb. Haemost. · Jan 2005
Multicenter StudyAccuracy of single-detector spiral CT in the diagnosis of pulmonary embolism: a prospective multicenter cohort study of consecutive patients with abnormal perfusion scintigraphy.
- M J L Van Strijen, W De Monye, G J Kieft, P M T Pattynama, M H Prins, and M V Huisman.
- Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands. strij007@wxs.nl
- J. Thromb. Haemost. 2005 Jan 1; 3 (1): 17-25.
BackgroundSpiral computed tomography (CT) has emerged as a potentially conclusive diagnostic test to exclude pulmonary embolism (PE) in patients with non-high probability scintigraphy and is already widely used-sometimes as the sole primary diagnostic test in the diagnosis of suspected PE. Its true sensitivity and specificity has, however, not been evaluated previously in a large cohort of consecutive patients.MethodsIn a multicenter prospective study 627 consecutive patients with clinically suspected PE were studied. Patients with normal perfusion scintigraphy were excluded from further analysis. Single-detector spiral CT scanning and ventilation scintigraphy were then performed in all patients to diagnose PE, while pulmonary angiography was performed as the gold standard. The only exceptions were those patients who had both a high-probability VQ scan and a CT scan positive for PE: these patients were considered to have PE and did not undergo additional pulmonary angiography. All imaging tests were read by independent expert panels.ResultsFive hundred and seventeen patients were available for complete analysis. The prevalence of PE was 32%. Spiral CT correctly identified 88 of 128 patients with PE, and 92 of 109 patients without PE, for a sensitivity and specificity of 69%[95% confidence interval (CI) 63-75] and 84% (95% CI 80-89), respectively. The sensitivity of spiral CT was 86% (95% CI 80-92) for segmental or larger PE and 21% (95% CI 14-29) in the group of patients with subsegmental PE.ConclusionThe overall sensitivity of spiral CT for PE is too low to endorse its use as the sole test to exclude PE. This holds true even if one limits the discussion to patients with larger PE in segmental or larger pulmonary artery branches. We conclude that, in patients with clinically suspected PE and an abnormal perfusion scintigraphy, single-slice detector spiral CT is not sensitive enough to be used as the sole test to exclude PE.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.