-
Scand J Trauma Resus · Jan 2015
Feasibility of LMA Supreme for airway management in unconscious patients by ALS paramedics.
- Sami Länkimäki, Seppo Alahuhta, Tom Silfvast, and Jouni Kurola.
- Helsinki Area Helicopter Emergency Medical Service, Helsinki University Central Hospital, FI-00029 HUS, Helsinki, Finland. sami.lankimaki@hus.fi.
- Scand J Trauma Resus. 2015 Jan 1;23:24.
BackgroundAirway management to ensure sufficient gas exchange is of major importance in emergency care. The accepted basic technique is to maintain an open airway and perform artificial ventilation in emergency situations is bag-valve mask (BVM) ventilation with manual airway management without airway adjuncts or with an oropharyngeal tube (OPA) only. Endotracheal intubation (ETI) is often referred to as the golden standard of airway management, but is associated with low success rates and significant insertion-related complications when performed by non-anaesthetists. Supraglottic devices (SADs) are one alternative to ETI in these situations, but there is limited evidence regarding the use of SAD in non-cardiac arrest situations. LMA Supreme (LMA-S) is a new SAD which theoretically has an advantage concerning the risk of aspiration due to an oesophageal inlet gastric tube port.MethodsForty paramedics were recruited to participate in the study. Adult (>18 years) patients, unconscious due to medical or traumatic cause with a GCS score corresponding to 3-5 and needed airway management were included in the study. Our aim was to study the feasibility of LMA-S as a primary airway method in unconscious patients by advanced life support (ALS) trained paramedics in prehospital care.ResultsThree regional Emergency Medical Service (EMS) services participated and 21 patients were treated during the survey. The LMA-S was placed correctly on the first attempt in all instances 21/21 (100%), with a median time to first ventilation of 9.8 s. Paramedics evaluated the insertion to be easy in every case 21/21 (100%). Because of air leak later in the patient care, the LMA-S was exchanged to an LT-D in two cases and to ETI in three cases (23.81%) by the paramedics. Regurgitation occurred after insertion two times out of 21 (9.52%) and in one of these cases (4.76%), paramedics reported regurgitation inside the LMA-S.ConclusionWe conclude that the LMA-S seems to be relatively easy and quick to insert in unconscious patients by paramedics. However, we found out that there were ventilation related problems with the LMA-S. Further studies are warranted.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.