Comparative Study
Administration of enoxaparin by continuous infusion in a naturalistic setting: analysis of renal function and safety.
- S L Kane-Gill, Y Feng, M B Bobek, R R Bies, M C Pruchnicki, and J F Dasta.
- Cleveland Clinic Foundation, USA. KaneSL@msx.upmc.edu
- J Clin Pharm Ther. 2005 Jun 1; 30 (3): 207-13.
Study ObjectiveTo describe the clinical use and safety of continuous infusion (CI) enoxaparin in a naturalistic setting and to evaluate the influence of renal function on enoxaparin elimination.DesignRetrospective medical record review.Setting1000-bed tertiary care teaching centre.PatientsHospitalized patients that received enoxaparin by CI during a 2-year period.InterventionsNone.MeasurementsSpecific details of dosage and monitoring were collected. Adverse drug reactions (ADR) were recorded. Creatinine clearance (CrCl) was calculated using Cockroft and Gault and Brater equations. A population pharmacokinetic analysis was performed using the non-linear mixed effect model (NONMEM). For patients located in the intensive care unit (ICU) and ward, POSTHOC pharmacokinetic parameter estimates were evaluated using the Wilcoxon rank-sum. Pearson correlation coefficient was calculated to determine the association between renal function and anti-Xa clearance.Main ResultsSixty-seven patients received enoxaparin by CI of which 61.2% were in the ward and 38.8% in the ICU. The average initial rate and duration of infusion were 5.2 mg/h and 5.6 days, respectively. The number of anti-Xa concentration measurements averaged five per patient. Nine patients experienced an ADR. The most frequent ADR was gastrointestinal bleeding (n = 4). Among the 67 patients, 48 had available anti-Xa concentrations and were included in the NONMEM model. The anti-Xa CL and volume of distribution for ICU and ward patients averaged 0.64 +/- 0.34 L/h, 10.6 +/- 1.55 L and 1.01 +/- 0.39 L/h, 9.08 +/- 1.17 L, respectively. CrCl was not a significant covariate when included in the NONMEM model, and the association between CrCl and anti-Xa clearance was not significant (R2 = 0.0005; P = 0.8916).ConclusionsThis study is the first to report the use and safety of prolonged CI enoxaparin. Pharmacokinetic parameters of enoxaparin differ in ICU vs. ward patients. Overall, we found the safety of CI to be comparable to subcutaneous administration. Also, we found no effect of renal function on enoxaparin elimination.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.