• J. Heart Lung Transplant. · Jan 2014

    Device thrombosis in HeartMate II continuous-flow left ventricular assist devices: a multifactorial phenomenon.

    • Nir Uriel, Jason Han, Kerry A Morrison, Nadav Nahumi, Melana Yuzefpolskaya, Arthur R Garan, Jimmy Duong, Paolo C Colombo, Hiroo Takayama, Sunu Thomas, Yoshifumi Naka, and Ulrich P Jorde.
    • Division of Cardiology, Department of Medicine, New York, New York. Electronic address: upj1@columbia.edu.
    • J. Heart Lung Transplant. 2014 Jan 1; 33 (1): 51-9.

    BackgroundContinuous-flow left ventricular assist devices (CF-LVADs) are increasingly used to support patients with advanced heart failure (HF). Device thrombosis is a serious complication of CF-LVADs, but its precise prevalence and etiology remains uncertain.MethodsRoot-cause analysis was performed in all cases with device thrombosis confirmed upon explant among patients implanted with a HeartMate II (HM II) from January 1, 2009 to November 15, 2012. Cannula position and bend relief integrity were assessed and charts were reviewed with particular attention to anti-coagulation and infection profiles.ResultsNineteen of 177 patients (11%) were found to have device thrombosis of various etiologies after a mean of 351 ± 311 days, representing 0.12 event/patient-year. Of the 5 mechanically induced thromboses, proximate etiology was severely abnormal inflow cannula position in 3 patients and bend relief disconnect with deformed outflow graft in 2 patients. One patient had a hypercoagulable disorder with prior arterial embolism. In the remaining 13 patients (age 61 ± 14 years, 77% male, 69% Caucasian), "non-mechanical" device thrombosis occurred after 357 ± 383 days; INR at the time of diagnosis was 1.81 (1.62 to 2.07); and mean device speed was 8,855 ± 359 rpm. Five of 13 patients (38%) had an infection during the month leading up to device thrombosis. Of note, lactate dehydrogenase (LDH) was already elevated at the time of discharge in patients who would later develop non-mechanical device thrombosis (423 [354 to 766] vs 352 [272 to 373] U/liter, p < 0.01).ConclusionsDevice thrombosis is a multifactorial phenomenon, and differentiation of mechanical and non-mechanical causes is an essential step for individual diagnosis and treatment plans. Larger studies excluding patients with obvious mechanical etiology are needed to investigate biologic and/or management-related risk factors for device thrombosis. Our findings suggest that LDH may be an early risk marker. Due to the difficulty in treating late-stage device thrombosis, we suggest early use of simple tests to rule out both causes of thrombosis, such as X-rays and closer LDH monitoring (bi-weekly).© 2014 International Society for Heart and Lung Transplantation Published by International Society for the Heart and Lung Transplantation All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…