• Spine J · Feb 2014

    Comparative Study

    Reliability of computer-assisted lumbar intervertebral measurements using a novel vertebral motion analysis system.

    • Matthew S Yeager, Daniel J Cook, and Boyle C Cheng.
    • Department of Neurosurgery, Allegheny General Hospital, 420 East North Ave., Suite 302, Pittsburgh, PA 15212, USA.
    • Spine J. 2014 Feb 1; 14 (2): 274-81.

    Background ContextTraditional methods for the evaluation of in vivo spine kinematics introduce significant measurement variability. Digital videofluoroscopic techniques coupled with computer-assisted measurements have been shown to reduce such error, as well as provide detailed information about spinal motion otherwise unobtainable by standard roentgenograms. Studies have evaluated the precision of computer-assisted fluoroscopic measurements; however, a formal clinical evaluation and comparison with manual methods is unavailable. Further, it is essential to establish reliability of novel measurements systems compared with standard techniques.PurposeTo determine the repeatability and reproducibility of sagittal lumbar intervertebral measurements using a new system for the evaluation of lumbar spine motion.Study DesignReliability evaluation of digitized manual versus computer-assisted measurements of the lumbar spine using motion sequences from a videofluoroscopic technique.Patient SampleA total of 205 intervertebral levels from 61 patients were retrospectively evaluated in this study.Outcome MeasuresCoefficient of repeatability (CR), limits of agreement (LOA), intraclass correlation coefficient (ICC; type 3,1), and standard error of measurement.MethodsIntervertebral rotations and translations (IVR and IVT) were each measured twice by three physicians using the KineGraph vertebral motion analysis (VMA) system and twice by three different physicians using a digitized manual technique. Each observer evaluated all images independently. Intra- and interobserver statistics were compiled based on the methods of Bland-Altman (CR, LOA) and Shrout-Fleiss (ICC, standard error of measurement).ResultsThe VMA measurements demonstrated substantially more precision compared with the manual technique. Intraobserver measurements were the most reliable, with a CR of 1.53 (manual, 8.28) for IVR, and 2.20 (manual, 11.75) for IVT. The least reliable measurements were interobserver IVR and IVT, with a CR of 2.15 (manual, 9.88) and 3.90 (manual, 12.43), respectively. The ICCs and standard error results followed the same pattern.ConclusionsThe VMA system markedly reduced variability of lumbar intervertebral measurements compared with a digitized manual analysis. Further, computer-assisted fluoroscopic imaging techniques demonstrate precision within the range of computer-assisted X-ray analysis techniques.Copyright © 2014 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…