-
Intensive care medicine · Jun 2000
Comparative Study Clinical Trial Controlled Clinical TrialCO assessment by suprasternal Doppler in critically ill patients: comparison with thermodilution.
- J Y Lefrant, M Benbabaali, J Ripart, A G Aya, G Sassi, M Dauzat, J E de La Coussaye, and J J Eledjam.
- Fédération d'Anesthésie Douleur Urgences Réanimation, Centre Hospitalier Universitaire de Nîmes, France.
- Intensive Care Med. 2000 Jun 1; 26 (6): 693-7.
ObjectiveComparison of suprasternal Doppler (SST) and thermodilution (TD) for the measurement of cardiac output (CO) in critically ill patients.DesignProspective study.SettingIntensive care unit of a university hospital.Patients And Participants65 consecutive critically ill patients requiring a pulmonary artery catheter.InterventionsPaired CO measurements were made simultaneously using SST and TD by two independent operators. The time to obtain a CO value by SST was measured. Correlation coefficients and the linear regression equation were determined. A Bland and Altman diagram was plotted. A Bland and Altman diagram was also plotted for the level of cardiac index (CI) values (low: CI < 2.5 l min(-1) m(-2); normal: 2.5 < or = CI < or = 4.5 l min(-1) m(-2); high: CI > 4.5 l min(-1) m(-2)).Measurements And ResultsIn seven patients SST failed to measure CO. In the remaining 58 patients 314 paired CO measurements were performed. The mean time to measure CO by SST was 73 +/- 45 s. The equation of linear regression was: SST(CO) = 0.84 TD(CO) + 1.39. The correlation coefficient was 0.84. The bias between SST and TD was -0.2 +/- 1.4 l min(-1). Biases were -0.23 +/- 0.50, -0.20 +/- 0.68, and 0.25 +/- 0.92 l min(-1) m(-2) for low, normal, and high levels of CI, respectively.ConclusionSST does not accurately measure CO but allows a rapid assessment of CI level in critically ill patients.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.