• J Clin Monit · Jul 1988

    Comparative Study

    Forehead pulse oximetry compared with finger pulse oximetry and arterial blood gas measurement.

    • E Y Cheng, M B Hopwood, and J Kay.
    • Department of Anesthesiology, Medical College of Wisconsin, Milwaukee 53226.
    • J Clin Monit. 1988 Jul 1; 4 (3): 223-6.

    AbstractUsual monitoring sites for pulse oximetry involve the fingers, toes, ear lobe, and nasal septum. This study examined the performance of a forehead sensor compared with a finger sensor for the pulse oximeter and arterial blood gas (ABG) analysis. Ten healthy adult volunteers and 22 ventilator-dependent patients were studied. The arterial oxygen saturation detected by forehead pulse oximetry (SpO2) correlated well with finger SpO2 and arterial oxygen saturation (SaO2) determined by arterial blood gas analysis in the healthy volunteers. Forehead SpO2 in mechanically ventilated patients correlated well with finger SpO2 and SaO2 when heart rate detected by pulse oximeter differed less than 10% from apical heart rate. Factors that caused a difference in oximeter-detected heart rate and apical heart rate were extensive tissue edema, head movement, and difficulty securing good tape placement. This suggests that when signal strength is weak, causing poor pulse rate detection, there will also be problems associated with accurate SpO2. The forehead pulse oximeter sensor works well on healthy, well-oxygenated volunteers. Difficulty was experienced when applying and using the sensor on critically ill patients. The reliability of the forehead pulse oximeter sensor has not been established at low saturations.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…