• J. Heart Lung Transplant. · Jan 2006

    Pediatric bridge to heart transplantation: application of the Berlin Heart, Medos and Thoratec ventricular assist devices.

    • Francisco A Arabía, Pei H Tsau, Richard G Smith, Paul E Nolan, Venki Paramesh, Raj K Bose, Daniel S Woolley, Gulshan K Sethi, Birger E Rhenman, and Jack G Copeland.
    • Department of Cardiothoracic Surgery, University of Arizona Sarver Heart Center, Tucson, Arizona 85724-5071, USA. arabiafrancisco@mayo.edu
    • J. Heart Lung Transplant. 2006 Jan 1; 25 (1): 16-21.

    BackgroundBridge to transplantation (BTT) is an accepted option when a donor heart is not available. Extensive clinical study has been done with BTT in the adult population, but comparatively fewer data are available in the pediatric population with regard to pulsatile devices.MethodsTen pediatric patients are presented, all of whom underwent BTT or recovery with pneumatic paracorporeal systems. The Berlin Heart bi-ventricular assist device (BVAD) was utilized in 1 patient, the Medos VAD in 4 patients (1 left ventricular assist device [LVAD], 3 BVADs) and the Thoratec VAD in 5 patients (3 BVADs, 2 LVADs). The pediatric population consisted of 3 females and 7 males. Mean age of the population was 7.4 years, weight 25 kg and body surface area (BSA) 0.88 m(2). Etiology for heart failure consisted of 4 viral, 3 congenital and 3 idiopathic cardiomyopathies. Before implant, all patients had evidence of progressive cardiac failure despite inotropic support, and 2 patients had been on extracorporeal membrane oxygenation (ECMO). Mean duration on the device was 34.3 days (8 to 107 days).ResultsTwo patients suffered stroke and recovered without sequelae. Two patients died of ischemic stroke and 1 of sepsis. Seven patients survived (6 transplanted and 1 weaned) for a survival rate of 70% compared with survival for ECMO as BTT, which was 40% to 50%. All survivors had complications related to bleeding, thromboembolic events and infections.ConclusionsThe Thoratec VAD can be placed in small patients with large hearts that can accommodate the available cannulas. The Berlin Heart and the Medos VAD have a selection of ventricles with small stroke volumes. All 3 systems can be used successfully in the pediatric population as BTT with better survival than with ECMO.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…