• Am. J. Cardiol. · Nov 2007

    Comparative Study

    Comparison of contrast agent-enhanced versus non-contrast agent-enhanced real-time three-dimensional echocardiography for analysis of left ventricular systolic function.

    • Boudewijn J Krenning, Sharon W Kirschbaum, Osama I I Soliman, Attila Nemes, Robert-Jan van Geuns, Wim B Vletter, Caroline E Veltman, Folkert J Ten Cate, Jos R T C Roelandt, and Marcel L Geleijnse.
    • Department of Cardiology, Erasmus Medical Center, Rotterdam, The Netherlands. b.krenning@erasmusmc.nl
    • Am. J. Cardiol. 2007 Nov 1; 100 (9): 1485-9.

    AbstractUltrasound contrast has shown to improve endocardial border definition. The purpose of this study was to evaluate the value of contrast agent-enhanced versus non-contrast agent-enhanced real-time 3-dimensional echocardiography (RT3DE) for the assessment of left ventricular (LV) volumes and ejection fraction. Thirty-nine unselected patients underwent RT3DE with and without SonoVue contrast agent enhancement and magnetic resonance imaging (MRI) on the same day. An image quality index was calculated by grading all 16 individual LV segments on a scale of 0 to 4: 0, not visible; 1, poor; 2, moderate; 3, good; and 4, excellent. The 3-dimensional data sets were analyzed offline using dedicated TomTec analysis software. By manual tracing, LV end-systolic volume, LV end-diastolic volume, and LV ejection fraction were calculated. After contrast agent enhancement, mean image quality index improved from 2.4 +/- 1.0 to 3.0 +/- 0.9 (p <0.001). Contrast agent-enhanced RT3DE measurements showed better correlation with MRI (LV end-diastolic volume, r = 0.97 vs 0.86; LV end-systolic volume, r = 0.96 vs 0.94; LV ejection fraction, r = 0.94 vs 0.81). The limits of agreement (Bland-Altman analysis) showed a similar bias for RT3DE images with and without contrast agent but with smaller limits of agreement for contrast agent-enhanced RT3DE. Also, inter- and intraobserver variabilities decreased. In a subgroup, patients with poor to moderate image quality showed an improvement in agreement after administration of contrast agent (+/-24.4% to +/-12.7%) to the same level as patients with moderate to good image quality without contrast agent (+/-10.4%). In conclusion, contrast agent-enhanced RT3DE is more accurate in assessment of LV function as evidenced by better correlation and narrower limits of agreement compared with MRI, as well as lower intra- and interobserver variabilities.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…