-
Fetal. Diagn. Ther. · Jan 2012
Comparative StudyComparison of Doppler-based and three-dimensional methods for fetal cardiac output measurement.
- Philip DeKoninck, Patricia Steenhaut, Tim Van Mieghem, Mina Mhallem, Jute Richter, Pierre Bernard, Luc De Catte, and Jan Deprest.
- Fetal Medicine Unit, Division of Woman and Child, Department of Obstetrics and Gynaecology, University Hospitals Leuven, Leuven, Belgium.
- Fetal. Diagn. Ther. 2012 Jan 1; 32 (1-2): 72-8.
ObjectiveFetal cardiac output is conventionally measured using two-dimensional (2D) and Doppler ultrasound (Doppler). New methods based on 3D measurements of ventricular size in systole and diastole have been proposed. Our aim was to validate these tools against the conventional Doppler-based methods.MethodsFetal combined cardiac output was prospectively measured at 16, 20, and 24 weeks of gestation in 15 uncomplicated pregnancies using Doppler and three different 3D algorithms [virtual organ computer-aided analysis (VOCAL), sonographic automatic volume calculation (SonoAVC), and inversion mode]. We determined the inter- and intraobserver variability of the 3D techniques and assessed the correlation between Doppler and 3D.ResultsThe 3D techniques showed adequate inter- and intraobserver reproducibility (intraclass correlation coefficient 0.69-0.98), with the best reproducibility for SonoAVC and inversion mode. Bland-Altman analysis revealed low bias and relatively good correlations when comparing the 3D methods among each other, albeit with wide 95% confidence intervals. Doppler measurement of fetal weight-adjusted combined cardiac output (349.0 ml·min⁻¹·kg⁻¹) yielded significantly higher results than 3D CO measurements (177.2, 160.7, and 174.0 ml·min⁻¹·kg⁻¹ for VOCAL, SonoAVC, and inversion mode, respectively; p < 0.0001) and correlated poorly with the 3D methods.ConclusionsAlthough 3D volume-based cardiac output measurements are reproducible, results obtained with different methods are not interchangeable. SonoAVC and inversion have the highest intra- and interobserver reproducibility. Results of cardiac output measurement by 3D and Doppler cannot be interchanged.Copyright © 2012 S. Karger AG, Basel.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.