-
Eur J Cardiothorac Surg · Mar 2006
Neurophysiological monitoring during thoracoabdominal aortic endovascular stent graft implantation.
- Ernst Weigang, Marc Hartert, Michael P Siegenthaler, Katrin Pitzer-Hartert, Maximilian Luehr, Ronen Sircar, Patrick von Samson, and Friedhelm Beyersdorf.
- Department of Cardiovascular Surgery, University Hospital Freiburg, Hugstetter Strasse 55, 79106 Freiburg, Germany. weigang@ch11.ukl.uni-freiburg.de
- Eur J Cardiothorac Surg. 2006 Mar 1; 29 (3): 392-6.
ObjectiveThe aim of this study was to evaluate the benefit of neurophysiological monitoring during thoracic and thoracoabdominal endovascular stent graft implantation.MethodsThe spinal cords of 21 patients undergoing endovascular stent graft implantation on the thoracic and thoracoabdominal aorta were monitored with transcranial motor-evoked potentials (tcMEP) and somatosensory-evoked potentials (SSEP). All patients underwent mild systemic hypothermia (34-35 degrees C), constant cerebrospinal fluid (CSF) pressure and vital parameter monitoring. If CSF pressure exceeded 15 mmHg, CSF-drainage was carried out.ResultsThree of the 21 patients (14%) exhibited short-term loss of tcMEP and SSEP after the deployment of the self-expanding endoprosthesis. We observed an intraoperative recovery of the evoked potentials in all cases. CSF-drainage was necessary in three of them. One patient, whose potentials were stable intraoperatively, developed paraparesis 3 weeks after the intervention.ConclusionsNeurophysiological monitoring has proved to be an ideal monitoring method to detect spinal cord ischemia during thoracic and thoracoabdominal endovascular stent graft implantation. Due to the advantages of endovascular therapy (no aortic cross-clamping, continuous distal perfusion, and no reperfusion injury), changes in potentials were seldom observed.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.