• J. Am. Coll. Cardiol. · Aug 1998

    The effects of ventricular fibrillation duration and site of initiation on the defibrillation threshold during early ventricular fibrillation.

    • J S Strobel, B H Kenknight, D L Rollins, W M Smith, and R E Ideker.
    • Department of Medicine, the University of Alabama at Birmingham, USA.
    • J. Am. Coll. Cardiol. 1998 Aug 1; 32 (2): 521-7.

    ObjectivesThe purpose of this study was to determine if the defibrillation threshold (DFT) is lower during the first few cycles of ventricular fibrillation (VF) than after 10 s of VF and, if so, if the effect is caused by local or global factors.BackgroundThe DFT may be low very early during VF because: (1) for the first few cycles VF arises from a localized region close to a defibrillation electrode where the shock field is strong (local factors), or (2) during early VF the effects of ischemia and sympathetic discharge have not yet fully developed and the heart has not yet completely dilated (global factors).MethodsProtocol 1 included seven pigs in which a defibrillation electrode and a pacing catheter were both placed in the right ventricular apex. VF was induced by delivering a high current premature stimulus from the pacing catheter that should have caused reentry confined to the right ventricular apex for the first few cycles of VF. A bipolar electrogram was recorded from the tip of the defibrillation catheter. Using a three reversal up-down protocol, the DFT was determined for biphasic shocks delivered after 1, 2, 3, 4, 5, 7, 10, 15, 20 and 25 activations in this electrogram and after 10 s (control). Protocol 2 included seven pigs undergoing the same procedure as in protocol 1 except that an additional pacing catheter was placed in the left ventricle. Defibrillation thresholds were determined after 1, 2, 3, 4 and 5 VF activations following VF induction from the right ventricle (RV) or the left ventricle (LV) and after 10 s (control).ResultsIn protocol 1, the mean +/- SD DFrs were lower during the first three cycles than after 10 s of VF (3.0 +/- 4.1 J for the first VF cycle vs 15.8 +/- 6.6 J after 10 s of VF, p < 0.05). In protocol 2, the DFF for the first few cycles of VF induced away from the defibrillation electrode in the LV (6.9 +/- 1.4 J for the first VF cycle) was significantly lower than that after 10 s of VF (16.0 +/- 2.2 J), whereas the DFF for the first few cycles induced near the defibrillation electrode in the right ventricular apex was significantly lower (2.3 +/- 2.7 J for the first VF cycle) than that induced from the LV.ConclusionsThis study demonstrates that the DFT is significantly lower during the first few VF cycles of VF than after 10 s of VF and that this decrease may be caused by both local factors and global factors. These results provide an impetus for exploring earlier shock delivery in implantable devices.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…