-
Sichuan Da Xue Xue Bao Yi Xue Ban · Jul 2013
[Image quality adapted thoracic diameters in CT coronary artery imaging].
- Xue-Lin Pan, Jia-Yua Sun, Wei Cheng, Kai-Hong Deng, Ju-Ying Zhang, Yun-Mei Luo, Hong-Li Bai, Jian-Qun Yu, Yuan Yuan, Li-Ping Deng, Tao Shuai, and Si-Meng Wang.
- Department of Radiology, West China Hospital, Sichuan University, Chengdu 610041, China.
- Sichuan Da Xue Xue Bao Yi Xue Ban. 2013 Jul 1; 44 (4): 578-83.
ObjectiveTo evaluate the correlation between image quality and thoracic diameters, anteroposterior diameter (AP) and right-left diameter (RL) for the optimization of reducing radiation dose in coronary artery imaging with Dual-source CT.Methods118 patients underwent CT coronary artery imaging (CTCA) were divided into two groups (A and B) according to body mass index (BMI). There were 58 patients in group A with BMI values > or = 25 kg/m2 and < 30 kg/m2; and 60 patients in group B with BMI values < 25 kg/m2. Scan parameters: collimation 64 X 0.6 mm, reconstruction slice thickness 0.75 mm, reconstructin interval 0.7 mm, FOV 150-180 mm, the pitch adjusted according to heart rate automatically. CT imagings were obtained with tube voltage 100 kV, tube current 330 mAs (group A) and 100 kV, tube current 220 mAs (group B). The contrast-noise ratio (CNR), signal to noise ratio (SNR), as well as blind correlation test score values were calculated to establish the relationship among BMI, AP, RL and CNR, SNR.ResultsRL of five levels in groups of A, B were correlated to CNRa (P < 0.05). In group A and B (except iii, iv level of Group A), AP were associated with CNRa (P < 0.05). In addition to ii, iv level of group A, v level of group B, BMI were associated with CNRa (P < 0.05). The correlation coefficient of CNRa and RL of group A except ii level was greater than that of CNRa and AP. The correlation coefficient of CNRa, SNRa and RL of group B was greater than that of CNRa, SNRa and AP. Except iii level, the correlation coefficient of CNRa, SNRa and AP of group A was greater than that of CNRa, SNRa and BMI. Except ii level, the correlation coefficient of CNRa and AP of group B was greater than that of CNRa and BMI.ConclusionThoracic diameter of RL can be used as a guider to select the appropriate scan protocol in the coronary imaging acqusition with dual-source CT.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.