• J Orthop Trauma · Oct 2012

    Comparative Study

    Lag screw fixation of medial malleolar fractures: a biomechanical, radiographic, and clinical comparison of unicortical partially threaded lag screws and bicortical fully threaded lag screws.

    • William M Ricci, Paul Tornetta, and Joseph Borrelli.
    • Department of Orthopaedic Surgery, Washington University School of Medicine, St. Louis, MO 63110, USA. ricciw@wudosis.wustl.edu
    • J Orthop Trauma. 2012 Oct 1; 26 (10): 602-6.

    ObjectivesBicortical fully threaded (FT) lag screw fixation (lag by method) is a technique for medial malleolar fixation that may provide advantages to partially threaded (PT) cancellous lag screws (lag by screw design). A direct comparison of the biomechanical properties and the clinical outcomes of these 2 methods of medial malleolar lag screw fixation were undertaken. The null hypotheses were that unicortical PT lag screws and bicortical FT lag screws had similar biomechanical and clinical outcomes.DesignBiomechanics--Human cadaver biomechanical investigation. Clinical-Retrospective cohort series with control. Settings-Level-1 trauma center.PatientsOne hundred forty-one consecutive patients with closed medial malleolar fractures (OTA 44) treated with lag screw fixation were identified from a prospective orthopaedic trauma database. Thirty-nine were lost to follow-up and 12 were treated with a single screw leaving 46 in the PT group and 46 in the FT group all treated with 2 screws for their medial malleolar fracture.InterventionBiomechanics--Human cadavers (n = 3) had bilateral oblique medial malleolar fractures (n = 6) created with an osteotome to simulate a typical medial malleolar fracture amenable to lag screw fixation. Fixation of each side was randomly allocated to either two 4.0-mm PT lag screws (length 45 mm) or two 3.5-mm FT threaded screws [length determined by depth gauge after near cortex overdrilled and far cortex (distal lateral tibia) drilled based on core diameter (2.7 mm)]. Clinical-Either 2 traditional PT (n = 46) or 2 FT screws (n = 46) were used for fixation of medial malleolus fractures.Main Outcome MeasurementsBiomechanics--Peak insertion torque generated during screw insertion. Clinical: Radiographic evidence of screw loosening, clinical non-union, and reoperation.ResultsBiomechanics--The FT lag screw group (n = 6 screws) showed an average maximum torque of 14.4 in-lbf (range 8.0-20.1, SD = 4.4) before screw stripping. This was over 3 times greater than that seen with the PT lag screws (n = 6) (average maximum torque generation = 4.0 in-lbf, range 2.5-6.6, SD = 1.4), P < 0.0002. Clinical-Radiographic screw loosening was evident in one of the 46 patients (2%) in the FT cohort and in 11 of the 46 patients (24%) in the PT cohort, P < 0.003. Two of the patients with screw loosening in the PT cohort required reoperation for removal of symptomatic hardware, whereas no patient from the LT screw group required removal. All patients in the LT cohort healed after the index procedure although 2 in the PT cohort had nonunions.ConclusionsScrews placed with the lag by method technique that engaged the distal lateral tibial cortex have superior biomechanical, radiographic, and clinical outcomes compared to traditional PT screws for the fixation of medial malleolar fractures.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.