• J. Cardiothorac. Vasc. Anesth. · Aug 2015

    Randomized Controlled Trial Observational Study

    The Precision of Pulmonary Artery Catheter Bolus Thermodilution Cardiac Output Measurements Varies With the Clinical Situation.

    • Idar Kirkeby-Garstad, Håkon Trønnes, Roar Stenseth, Olav F M Sellevold, Petter Aadahl, and Eirik Skogvoll.
    • Department of Anesthesiology and Intensive Care, St. Olav University Hospital, Trondheim, Norway. Electronic address: Idar.Kirkeby-Garstad@ntnu.no.
    • J. Cardiothorac. Vasc. Anesth. 2015 Aug 1; 29 (4): 881-8.

    ObjectiveTo investigate the effects of ventilatory mode, injectate temperature, and clinical situation on the precision of cardiac output measurements.DesignRandomized, prospective observational study.SettingSingle university hospital.ParticipantsForty patients undergoing planned cardiac surgery, receiving a pulmonary artery catheter according to institutional routine.InterventionsCardiac output was measured at 4 predefined time points during the perioperative patient course, twice during controlled and twice during spontaneous ventilation, using 2 blocks of 8 measurement replications with cold and tepid injectate in random order.Measurements And Main ResultsThe data were analyzed using a hierarchical linear mixed model. Clinical precision was determined as half the width of the 95% confidence interval for the underlying true value. The single-measurement precision measured in 2 different clinical situations for each temperature/ventilation combination was 8% to 10%, 11% to 13%, 13% to 15%, and 23% to 24% in controlled ventilation with cold injectate, controlled ventilation with tepid injectate, spontaneous breathing with cold injectate, and spontaneous breathing with tepid injectate, respectively. Tables are provided for the number of replications needed to achieve a certain precision and for how to identify significant changes in cardiac output.ConclusionsClinical precision of cardiac output measurements is reduced significantly during spontaneous relative to controlled ventilation. The differences in precision between repeated measurement series within the temperature/ventilation combinations indicate influence of other situation-specific factors not related to ventilatory mode. Compared with tepid injectate in patients breathing spontaneously, the precision is 3-fold better with cold injectate and controlled ventilation.Copyright © 2015 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…