• Can J Anaesth · Jul 2012

    Comparative Study

    Less leakage and dislodgement with a catheter-over-needle versus a catheter-through-needle approach for peripheral nerve block: an ex vivo study.

    • Jenkin Tsui.
    • Department of Anesthesiology and Pain Medicine, University of Alberta, Edmonton, Canada. btsui@ualberta.ca
    • Can J Anaesth. 2012 Jul 1;59(7):655-61.

    PurposeThe objective of this study was to compare the catheter-through-needle (CTN) and catheter-over-needle (CON) catheterization techniques ex vivo by measuring leak pressure around the catheter and the catheter's resistance to pulling force.MethodsUsing an ex vivo porcine limb model, we compared the conventional CTN design with the CON design with respect to the ability to resist leakage at the catheter insertion site under high injection pressure and the force required to withdraw the catheter from tissue. One CON assembly (MultiSet, Pajunk) and three CTN assemblies (Contiplex, B.Braun; StimuCath, Arrow; Stimulong Sono, Pajunk) were studied. Ten porcine hind limbs were used to test leakage and another ten were used to measure withdrawal force. Catheters were placed at angles of 15° and 30° at depths of 3 cm and 5 cm. Leakage was assessed visually at the insertion site, and pressure was measured at the moment leakage occurred. Withdrawal force was measured by pulling the catheter from the tissue.ResultsNo evidence of leakage was detected at the CON catheter insertion site at the highest pressure applied (1,000 mmHg) (n = 40). The CON assembly withstood significantly higher injection pressure than the CTN catheters without causing leaks at the catheter insertion site [CON, mean (standard deviation) > 1,000 (0) mmHg; B.Braun, 596 (92) mmHg; Pajunk Stimulong, 615 (107) mmHg; and Arrow, 422 (104) mmHg; P < 0.001 CON vs CTN]. The force required to withdraw the catheter from the porcine limb was greater with CON catheters [3.8 (0.8) N] than with any of the CTN catheters [range, 0.4 (0.2) - 0.8 (0.2) N], depending on depth, angle, and manufacturer (P < 0.001 CON vs CTN).ConclusionIn the porcine leg model, CON catheterization provides greater resistance to leakage under high injection pressure and greater holding force in tissue than traditional CTN catheters.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.