J. Thorac. Cardiovasc. Surg. · Jan 1999
Ventriculoarterial coupling with intra-aortic balloon pump in acute ischemic heart failure.
- O Kawaguchi, W E Pae, B B Daily, and W S Pierce.
- Department of Surgery, Division of Cardiothoracic Surgery, College of Medicine, The Pennsylvania State University, The Milton S. Hershey Medical Center, Hershey, PA 17033, USA.
- J. Thorac. Cardiovasc. Surg. 1999 Jan 1; 117 (1): 164-71.
PurposeWe analyzed the mechanism of effects of intra-aortic balloon pumping using the pressure-volume relationship and ventriculoarterial coupling in the normal and failing hearts.MaterialsIn 12 anesthetized Holstein calves (weight, 94 +/- 8 kg), the ventricular end-systolic and arterial elastances, pressure-volume area, and external work were analyzed during steady-state contractions with traditional hemodynamic parameters with intra-aortic balloon pumping-off and -on (1:1 synchronous ratio). An acute ischemic heart failure was induced by injecting 10 microm microspheres (4.2 +/- 1.8 x 10(7). 100g left ventricular weight-1) into the left main coronary artery; all measurements were repeated.ResultsIntra-aortic balloon pumping did not change hemodynamic parameters in the control. However, during heart failure, intra-aortic balloon pumping decreased the arterial elastance from 3.6 +/- 1.3 mm Hg to 2.9 +/- 1.2 mm Hg. mL-1 while not affecting the ventricular end-systolic elastance, this resulted in an improvement of the ventriculoarterial coupling ratio from 3.1 +/- 0.8 to 2.3 +/- 0.8. Intra-aortic balloon pumping decreased not only end-systolic pressure (from 69 +/- 16 mm Hg to 64 +/- 19 mm Hg) but end-diastolic volume and pressure (from 139 +/- 38 mL to 137 +/- 37 mL and from 13. 9 mm Hg to 12.8 mm Hg, respectively) with the leftward shift of the pressure-volume loop. Pressure-volume area decreased (from 914 +/- 284 mm Hg to 849 +/- 278 mm Hg. mL) although stroke volume increased (from 21 +/- 6 mL to 24 +/- 6 mL).ConclusionReduction of the arterial elastance with intra-aortic balloon pumping improved the ventriculoarterial coupling ratio and increased stroke volume. Leftward shift of the pressure-volume loop resulted in the reduction of pressure-volume area, which suggests the conservation of the myocardial oxygen consumption.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.