Journal of neurotrauma · Apr 2002
Fiberoptic intraparenchymal brain pressure monitoring with the Camino V420 monitor: reflections on our experience in 163 severely head-injured patients.
- Maria-Antonia Poca, Juan Sahuquillo, Mercedes Arribas, Marcelino Báguena, Sonia Amorós, and Enrique Rubio.
- Department of Neurosurgery, Vall d'Hebron University Hospital, Barcelona, Spain. pocama@wanadoo.es
- J. Neurotrauma. 2002 Apr 1; 19 (4): 439-48.
AbstractTo assess the safety and accuracy of the Camino intraparenchymal sensor, we prospectively evaluated hemorrhagic complications, zero-drift, infection, and system malfunction in 163 patients monitored after a severe head injury. Mean duration of intracranial pressure (ICP) monitoring was 5 +/- 2.2 days (range: 12 h to 11 days). Of the 141 patients with a control CT scan, four showed a 1-2-cc collection of blood at the catheter's end. When removed, the sensors underread the true ICP value (negative zero-drift) in 80 of the 126 sensors evaluated (63.5%). Fourteen sensors showed no zero-drift, and 32 sensors overread the true ICP value (positive zero-drift) (median: -1 mm Hg; interquartile range: -4 to +1 mm Hg). No significant relationship was found between zero-drift, the surgeon who implanted the sensor, intracranial hypertension, or duration of ICP monitoring. No clinical infections could be attributed to the devices. Sixteen patients (9.8%) required more than one ICP sensor due to malfunctioning of the system. In conclusion, continuous ICP monitoring using the Camino intraparenchymal sensor has a low complication rate. However, this sensor may underread the real ICP values in a high number of patients. The lack of correlation between duration of ICP monitoring and zero-drift suggests that, contrary to the recommendations of other reports, the intraparenchymatous Camino sensor can provide reliable readings after the fifth day of use.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.