-
- John C Sakles, Parisa P Javedani, Eric Chase, Jessica Garst-Orozco, Jose M Guillen-Rodriguez, and Uwe Stolz.
- Department of Emergency Medicine, University of Arizona College of Medicine, Tucson, AZ.
- Acad Emerg Med. 2015 Jun 1; 22 (6): 700-7.
ObjectivesThe purpose of this investigation was to compare the incidence of esophageal intubations (EIs) when emergency medicine (EM) residents used a direct laryngoscope (DL) versus a video laryngoscope (VL) for intubation attempts in the emergency department (ED).MethodsProspectively collected continuous quality improvement data on tracheal intubations performed by EM residents in an academic ED over a 6-year period were retrospectively analyzed. Following each intubation, EM residents completed a data form with patient, intubation, and operator characteristics. Data collected included the method of intubation, drugs used, device(s) used, number of attempts, outcome of each attempt, occurrence of EIs, and occurrence of adverse events (hypoxemia, aspiration, dysrhythmia, hypotension, and cardiac arrest). The incidence of EI was compared between intubation attempts with a DL and with a VL (GlideScope(®) or C-MAC(®) ). Propensity score matching and conditional logistic regression were used to analyze the association between the intubation device (DL vs. VL) and EI.ResultsOver the 6-year period, 2,677 patients underwent 3,425 intubation attempts by EM residents with a DL or a VL. A DL was used in 1,530 attempts (44.7%) and a VL was used in 1,895 attempts (55.3%). There were 96 recognized EIs (2.8%). The incidence of EI when using a DL was 78 of 1,530 attempts (5.1%; 95% confidence interval [CI] = 4.1% to 6.3%) and when using a VL was 18 of 1,895 attempts (1.0%; 95% CI = 0.6% to 1.5%). Based on the propensity score matched analysis, the odds ratio for the occurrence of an EI for DL versus VL was 6.9 (95% CI = 3.3 to 14.4). Patients who had inadvertent EIs had a higher incidence of adverse events (49.5%; 95% CI = 38.9% to 60.0%) than patients in which EI did not occur (19.8%; 95% CI = 18.3% to 21.4%).ConclusionsThe use of a VL by EM residents during an intubation attempt in the ED was associated with significantly fewer EIs compared to when a DL was used. Patients who had inadvertent EIs had significantly more adverse events than those who did not have EIs. EM residency training programs should consider using VLs for ED intubations to maximize patient safety when EM residents are performing intubation.© 2015 by the Society for Academic Emergency Medicine.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.