• Int J Stroke · Feb 2013

    Comparative Study

    Stent design lowers angiographic but not clinical adverse events in stenting of symptomatic intracranial stenosis - results of a single center study with 100 consecutive patients.

    • S Rohde, J Seckinger, S Hähnel, P A Ringleb, M Bendszus, and M Hartmann.
    • Department of Neuroradiology, University of Heidelberg Medical Center, Heidelberg, Germany. stefan.rohde@med.uni-heidelberg.de
    • Int J Stroke. 2013 Feb 1; 8 (2): 87-94.

    Background And AimsComparing safety and technical success of balloon-expandable stents and self-expanding stents for intracranial angioplasty and stenting in medically refractory intracranial atherosclerotic disease in a single center series.MethodsFifty-four self-expanding stents and 46 balloon-expandable stents were implanted in 100 consecutive patients (mean age 64 years, 74% male) from April 2000 to September 2009. All patients had symptomatic intracranial stenosis (anterior circulation, n = 40; posterior circulation, n = 60), presenting with recurrent transient ischemic attack or stroke under antithrombotic treatment. Mean degree of stenosis before treatment was 83 ± 13%. We assessed safety, defined as any stroke or death during the procedure and at 30 days follow-up, and technical success, defined as accurate delivery of the stent at the site of the target lesion.ResultsSafety - periprocedural stroke or hemorrhage occurred in 11 patients treated with balloon-expandable stent, and in 14 of the patients treated with a self-expanding stent. One patient with a balloon-expandable stent died because of acute vessel rupture during treatment. One balloon-expandable stent and one self-expanding stent patient developed a severe reperfusion hemorrhage that resulted in death. Overall, the combined stroke and death rate at 30-day follow-up was 25·0% (23·9% for balloon-expandable stent group and 25·9% for the self-expanding stent group, P = 0·84). Technical success - intracranial angioplasty and stenting was technically successful in 96·3% of the self-expanding stent and 89·1% of the balloon-expandable stent patients (P = 0·31). Vascular complications were significantly less frequent in patients treated with a self-expanding stent (11·1%) than with a balloon-expandable stent (36·9%, P = 0·002).ConclusionDespite a high technical success, the rate of clinical adverse events at 30 days after intracranial angioplasty and stenting is high independently of the stent design. Thus, further development of intracranial stent systems and careful patient selection are mandatory.© 2012 The Authors. International Journal of Stroke © 2012 World Stroke Organization.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…