• Acad Emerg Med · Jan 2011

    The interrater reliability of inferior vena cava ultrasound by bedside clinician sonographers in emergency department patients.

    • J Matthew Fields, Paul A Lee, Katherine Y Jenq, Dustin G Mark, Nova L Panebianco, and Anthony J Dean.
    • Department of Emergency Medicine, University of Pennsylvania, Philadelphia, PA, USA.
    • Acad Emerg Med. 2011 Jan 1; 18 (1): 98-101.

    ObjectivesInferior vena cava ultrasound (IVC-US) is a noninvasive bedside tool to assess intravascular volume status. This study set out to investigate the interrater reliability of IVC-US by bedside clinician sonographers and determine whether alternative methods of IVC-US such as B-mode and visual estimation are equally reliable to traditional M-mode.MethodsA convenience sample of adult emergency department (ED) patients was prospectively enrolled. Each patient underwent IVC-US by two different emergency physicians (EPs), each of whom first performed visual estimation of IVC percent collapse and of volume status, followed by caliper measurements in M-mode and B-mode. EPs were blinded to patient data and to the other sonographer's results. For each technique, interrater reliability was determined between the two EPs' assessments using intraclass correlation coefficients (ICC) for continuous data and Cohen's weighted kappa for categorical data. In addition, analysis was performed on M-mode diameter measurements to determine the relationship between sonographer and patient characteristics on interrater reliability.ResultsFive EPs performed 92 US exams on 46 patients. Using M-mode, the ICC for maximum IVC diameter was 0.81 (95% confidence interval [CI]=0.67 to 0.89), and for minimum diameter was 0.77 (95% CI=0.62 to 0.87). There were no statistically significant differences between the caliper methods used for IVC measurements (M-mode diameter, B-mode diameter, or B-mode area). Agreement for visually estimated IVC collapse (0.60, 95% CI=0.36 to 0.76) was similar to agreement for calculated M-mode IVC collapse index (0.52, 95% CI=0.27 to 0.71). Cohen's weighted kappa for volume status based on visual estimation of IVC filling (size, shape, and collapse) was 0.64 (95% CI=0.53 to 0.73). ICC values for M-mode diameter measurements were significantly higher in studies involving patients who were noneuvolemic and studies in which sonographers had each performed at least five prior IVC-US.ConclusionsEmergency physicians' US measurements of IVC diameter have a high degree of interrater reliability. IVC percent collapse by visual estimation or based on caliper measurements have lower, but still moderate to good reliability. The use of the visual estimation technique should be considered by clinicians who have learned to obtain measured parameters of IVC filling because it is equally reliable to traditional M-mode and can be performed more rapidly.© 2010 by the Society for Academic Emergency Medicine.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.