• J Clin Monit Comput · Oct 2007

    Clinical validation of a digital transcutaneous PCO2/SpO2 ear sensor in adult patients after cardiac surgery.

    • Werner Baulig, Philipp Schütt, Hans R Roth, Josef Hayoz, and Edith R Schmid.
    • Division of Cardiac Anaesthesia, Institute of Anaesthesiology, University Hospital of Zurich, Raemistrasse 100, Zurich, 8091, Switzerland. werner.baulig@usz.ch
    • J Clin Monit Comput. 2007 Oct 1; 21 (5): 303-9.

    ObjectiveThe aim of this study was to validate the V-Sign digital sensor (SenTec AG, Therweil, Switzerland) for combined noninvasive assessment of pulse oxymetric oxygen saturation (SpO(2)) and transcutaneous carbon dioxide tension (PtcCO(2)) in adults after cardiac surgery.MethodsIn twenty one patients, aged 51-86 years, simultaneous measurements of blood gases with the V-Sign Sensor and with two Nellcor Durasensors (model DS-100A), one at the opposite earlobe and one with a finger clip, were compared first during hyper-, normo- and hypocapnia and at different pulse rates using a pacemaker, and then at 2-h intervals up to 8 h. Agreement was assessed by Bland-Altman analysis.ResultsPtcCO(2) data of three patients were excluded because of calibration failure of the device. Median (range) PtcCO(2) for the remaining patients was 5.49 (3.3-7.6) kPa and arterial carbon dioxide tension (PaCO(2)) was 5.43 (3.61-7.41) kPa. Corresponding mean bias was +0.05 kPa and limits of agreement (LOA) were -1.2/+1.3 kPa. During normo- and hypoventilation, mean bias was good at +0.02 and +0.04 kPa respectively, but limits of agreement were poor at -0.67/+0.69 and -0.81/+0.88 kPa. In 10 patients, an initial overshoot of PtcCO(2 )was observed. Mean bias of SpO(2) and pulse rate was close to zero (-1.5% and +0.001 bpm respectively), but limits of agreement were unacceptably high (-21.4/+18.4% and -22.3/+22.3 bpm).ConclusionsIn the present state of development the SenTeC Digital monitor V-Sign device has serious limitations. Additional efforts are necessary to eliminate calibration failures and the initial overshoot of PtcCO(2) as well as to improve detection of SpO(2) and pulse rate.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.