• Rev Bras Anestesiol · Feb 2004

    Influence of stimulation frequency on rocuronium and pancuronium-induced neuromuscular block onset. Acceleromyography evaluation.

    • Derli da Conceição Munhóz, Angélica de Fátima de Assunção Braga, and Glória Maria Braga Potério.
    • Departamento de Anestesiologia da Faculdade de Ciências Médicas da UNICAMP, Campinas, SP.
    • Rev Bras Anestesiol. 2004 Feb 1; 54 (1): 3-12.

    Background And ObjectivesFactors associated to patients and neuromuscular blockers (NMB), as well as others inherent to neuromuscular function monitoring, may affect neuromuscular block onset. This study aimed at the influence of two different stimulation frequencies on rocuronium and pancuronium-induced neuromuscular block.MethodsParticipated in this study 120 patients, physical status ASA I and II, submitted to elective procedures under general anesthesia, who were randomly allocated in two groups, according to the stimulation frequency employed to monitor neuromuscular block: Group I - 0.1 Hz (n = 60) and Group II - 1 Hz (n = 60). Two subgroups were formed within each group (n = 30), according to the neuromuscular blocker: Subgroup P (pancuronium) and Subgroup R (rocuronium). Patients were premedicated with muscular midazolam (0.1 mg kg(-1)), 30 minutes before surgery. Anesthesia was induced with propofol (2.5 mg kg(-1)) preceded by alfentanil (50 microg kg(-1)) and followed by pancuronium or rocuronium. Patients were ventilated under mask with 100% oxygen until 75% or more decrease in adductor pollicis muscle response, when laryngoscopy and tracheal intubation were performed. Neuromuscular function was monitored by acceleration transducer. The following parameters were evaluated: pancuronium and rocuronium onset time; time for complete block and tracheal intubation conditions.ResultsMean times (seconds) for pancuronium-induced neuromuscular block onset and for complete neuromuscular block were: Group I (159.33 +/- 35,22 and 222 +/- 46.56) and Group II (77.83 +/- 9.52 and 105.96 +/- 15.58); rocuronium-induced values were: Group I (83 +/- 17.25 and 125.33 +/- 20.12) and Group II (48.96 +/- 10.16 and 59.83 +/- 10.36) with statistical difference between groups. Tracheal intubation conditions were satisfactory in 117 patients (97.5%) and unsatisfactory in 3 (2.5%).ConclusionsRocuronium and pancuronium-induced neuromuscular block onset and time required for complete adductor pollicis muscle neuromuscular block are shorter when higher stimulation frequencies are applied.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…