-
Randomized Controlled Trial
Evaluation of low tidal volume with positive end-expiratory pressure application effects on arterial blood gases during laparoscopic surgery.
- Elif Dogan Baki, Serdar Kokulu, Ahmet Bal, Yüksel Ela, Remziye Gül Sivaci, Murat Yoldas, Fatih Çelik, and Nilgun Kavrut Ozturk.
- Department of Anesthesiology, Afyon Kocatepe University, Faculty of Medicine, Afyon, Turkey. Electronic address: elifbaki1973@mynet.com.
- J Chin Med Assoc. 2014 Jul 1; 77 (7): 374-8.
BackgroundPneumoperitoneum (PNP) and patient positions required for laparoscopy can induce pathophysiological changes that complicate anesthetic management during laparoscopic procedures. This study investigated whether low tidal volume and positive end-expiratory pressure (PEEP) application can improve ventilatory and oxygenation parameters during laparoscopic surgery.MethodsA total of 60 patients undergoing laparoscopic surgery were randomized to either the conventional group (n = 30, tidal volume = 10 mL/kg, rate = 12/minute, PEEP = 0 cm H(2)O) or the low tidal group with PEEP group (n = 30, tidal volume = 6 mL/kg, rate = 18/minute, PEEP = 5 cm H(2)O) at maintenance of anesthesia. Hemodynamic parameters, peak plateau pressure (Pplat) and arterial blood gases results were recorded before and after PNP.ResultsThere was a significant increase in the partial pressure of arterial carbon dioxide (PaCO(2)) values after PNP in the conventional group in the reverse Trendelenburg (41.28 mmHg) and Trendelenburg positions (44.80 mmHg;p = 0.001), but there was no difference in the low tidal group at any of the positions (36.46 and 38.56, respectively). We saw that PaO(2) values recorded before PNP were significantly higher than the values recorded 1 hour after PNP in the two groups at all positions. No significant difference was seen in peak inspiratory pressure (Ppeak) at the reverse Trendelenburg position before and after PNP between the groups, but there was a significant increase at the Trendelenburg position in both groups (conventional; 21.67 cm H(2)O, p = 0.041, low tidal; 23.67 cm H(2)O, p = 0.004). However, Pplat values did not change before and after PNP in the two groups at all positions.ConclusionThe application of low tidal volume + PEEP + high respiratory rate during laparoscopic surgeries may be considered to improve good results of arterial blood gases.Copyright © 2014. Published by Elsevier B.V.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.