-
- N J Vogelzang, M Ruane, and T R DeMeester.
- J. Clin. Oncol. 1985 Mar 1; 3 (3): 407-14.
AbstractA second generation, implantable drug administration device (DAD, Medtronic, Inc, Minneapolis) which contains a 20-mL drug reservoir, a lithium-thionyl-chloride battery, a peristaltic roller pump, a microprocessor circuit, and an acoustic transducer has entered clinical trials. After surgical placement, drug is entered into and removed from the DAD percutaneously through a Silastic "fill port" using a standard gauge needle and syringe. The pump is noninvasively programmed using a hand-held telemetry wand to administer the drug in a continuous infusion, bolus, or bolus-delay mode. Because of the apparent improved therapeutic index of continuous-infusion doxorubicin (CID), a phase I trial of the Medtronic DAD with CID was begun. Thirteen pumps in 13 patients have functioned for a median of 153 days (range, 11 to 395 days) with one pump still functioning. Four pumps ceased function at 170, 278, 331, and 370 days, respectively; there was a catheter-tip clot on one of the pumps that later malfunctioned. All other pumps functioned until the death of the respective patients. In 84 pump refills, without drug extravasation, the median drug delivery error (actual residual volume--calculated residual volume/calculated residual volume X 100%) was 14%. Doxorubicin was compatible with all components of the drug pathway and did not significantly decompose during two weeks in the drug reservoir. The starting dose of CID was 2.0 mg/m2/d and the maximum tolerated dose was 4.1 mg/m2/d (range, 3.5 to 5.5). A median cumulative doxorubicin dose of 244 mg/m2 per patient (range, 10 to 583 mg/m2) has been infused.(ABSTRACT TRUNCATED AT 250 WORDS)
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.