• Semin. Thorac. Cardiovasc. Surg. · Jan 1998

    Review

    Monitoring of somatosensory evoked potentials: a primer on the intraoperative detection of spinal cord ischemia during aortic reconstructive surgery.

    • R R Robertazzi and J N Cunningham.
    • Department of Surgery, Maimonides Medical Center, Brooklyn, NY 11219, USA.
    • Semin. Thorac. Cardiovasc. Surg. 1998 Jan 1; 10 (1): 11-7.

    AbstractThe acute interruption of blood supply to the spinal cord during thoracic and thoracoabdominal aortic reconstructions, if unabated, inevitably causes neurological injury secondary to regional hypoxia. Techniques that address the multifactorial nature of spinal cord ischemic injury have evolved to preserve neuromotor function. However, the overall incongruity of the spinal cord's vascular anatomy makes it virtually impossible to predict, with any degree of certainty, the duration of aortic cross-clamping (AXC) that can safely be endured. The sensitivity of evoked potential monitoring to the disruption of spinal cord perfusion has led to the emergence of this modality as an effective tool at the surgeon's disposal for the intraoperative assessment of distal aortic perfusion and cord viability during proximal AXC. Somatosensory evoked potentials (SSEP) provide invaluable diagnostic data as to the status of cord function, through the continuous appraisal of signal amplitude and latency. A latency increase, as small as 10% of the pre-AXC value, is linked to a reduction of spinal cord perfusion pressure and thereby associated with a high incidence of neurological impairment. Four discrete types of SSEP responses have been identified to represent differing surgical scenarios during AXC. The Type I response (deterioration of SSEP within 3 to 5 minutes) is indicative of a failure to maintain a distal pressure of at least 60 mm Hg, whereas a Type II signifies adequate distal aortic perfusion. Sudden loss of signal as witnessed in a Type III SSEP implies compromised critical intercostal vessels and indicates their expeditious reimplantation. A gradual (30 to 50 minutes) SSEP "fadeout" corresponds to marginal distal perfusion, suggesting the presence of extensive pathology. Intraoperative evoked potential monitoring, in conjunction with distal aortic perfusion, permits rapid identification and correction of compromised spinal cord blood flow, permitting repair of aortic lesions without the added liability of time constraints.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.