• J. Thorac. Cardiovasc. Surg. · Nov 2011

    Hemodynamics and myocardial blood flow patterns after placement of a cardiac passive restraint device in a model of dilated cardiomyopathy.

    • Jennifer A Dixon, Amy M Goodman, William F Gaillard, William T Rivers, Richard A McKinney, Rupak Mukherjee, Nathaniel L Baker, John S Ikonomidis, and Francis G Spinale.
    • Division of Cardiothoracic Surgery, Medical University of South Carolina and Ralph H. Johnson Veterans Affairs Medical Center, Charleston, SC, USA.
    • J. Thorac. Cardiovasc. Surg. 2011 Nov 1; 142 (5): 1038-45.

    BackgroundThe present study examined a cardiac passive restraint device which applies epicardial pressure (HeartNet Implant; Paracor Medical, Inc, Sunnyvale, Calif) in a clinically relevant model of dilated cardiomyopathy to determine effects on hemodynamic and myocardial blood flow patterns.MethodsDilated cardiomyopatht was established in 10 pigs (3 weeks of atrial pacing, 240 beats/min). Hemodynamic parameters and regional left ventricular blood flow were measured under baseline conditions and after acute placement of the HeartNet Implant. Measurements were repeated after adenosine infusion, allowing maximal coronary vasodilation and coronary flow reserve to be determined.ResultsLeft ventricular dilation and systolic dysfunction occurred relative to baseline as measured by echocardiography. Left ventricular end-diastolic dimension increased and left ventricular fractional shortening decreased (3.8 ± 0.1 vs 6.1 ± 0.2 cm and 31.6% ± 0.5% vs 16.2% ± 2.1%, both P < .05, respectively), consistent with the dilated cardiomyopathy phenotype. The HeartNet Implant was successfully deployed without arrhythmias and a computed median mid-left ventricular epicardial pressure of 1.4 mm Hg was applied by the HeartNet Implant throughout the cardiac cycle. Acute HeartNet placement did not adversely affect steady state hemodynamics. With the HeartNet Implant in place, coronary reserve was significantly blunted.ConclusionsIn a large animal model of dilated cardiomyopathy, the cardiac passive restraint device did not appear to adversely affect basal resting myocardial blood flow. However, after acute HeartNet Implant placement, left ventricular maximal coronary reserve was blunted. These unique results suggest that cardiac passive restraint devices that apply epicardial transmural pressure can alter myocardial blood flow patterns in a model of dilated cardiomyopathy. Whether this blunting of coronary reserve holds clinical relevance with chronic passive restraint device placement remains unestablished.Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…