Virtual reality myringotomy simulation with real-time deformation: development and validity testing.
- Andrew K Ho, Hussain Alsaffar, Philip C Doyle, Hanif M Ladak, and Sumit K Agrawal.
- Biomedical Engineering Graduate Program, University of Western Ontario, London, Ontario, Canada.
- Laryngoscope. 2012 Aug 1; 122 (8): 1844-51.
Objectives/HypothesisSurgical simulation is becoming an increasingly common training tool in residency programs. The first objective was to implement real-time soft-tissue deformation and cutting into a virtual reality myringotomy simulator. The second objective was to test the various implemented incision algorithms to determine which most accurately represents the tympanic membrane during myringotomy.Study DesignDescriptive and face-validity testing.MethodsA deformable tympanic membrane was developed, and three soft-tissue cutting algorithms were successfully implemented into the virtual reality myringotomy simulator. The algorithms included element removal, direction prediction, and Delaunay cutting. The simulator was stable and capable of running in real time on inexpensive hardware. A face-validity study was then carried out using a validated questionnaire given to eight otolaryngologists and four senior otolaryngology residents. Each participant was given an adaptation period on the simulator, was blinded to the algorithm being used, and was presented the three algorithms in a randomized order.ResultsA virtual reality myringotomy simulator with real-time soft-tissue deformation and cutting was successfully developed. The simulator was stable, ran in real time on inexpensive hardware, and incorporated haptic feedback and stereoscopic vision. The Delaunay cutting algorithm was found to be the most realistic algorithm representing the incision during myringotomy (P < .05). The Likert and visual analog scales had strong correlations, suggesting good internal reliability.ConclusionsThe first virtual reality myringotomy simulator is being developed and now integrates a real-time deformable tympanic membrane that appears to have face validity. Further development and validation studies are necessary before the simulator can be studied with respect to training efficacy and clinical impact.Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.