• BMC anesthesiology · Oct 2015

    Observational Study

    Prevalence and predictors of out-of-range cuff pressure of endotracheal and tracheostomy tubes: a prospective cohort study in mechanically ventilated patients.

    • Amer R Alzahrani, Shatha Al Abbasi, Othman Khalid Abahoussin, Tariq Othman Al Shehri, Hasan M Al-Dorzi, Hani M Tamim, Musharaf Sadat, and Yaseen M Arabi.
    • Intensive Care Department; King Abdulaziz Medical City, King Saud bin Abdulaziz University for Health Sciences, P.O. Box 22490, Riyadh, 11426, Kingdom of Saudi Arabia. Amer.md.rrt@gmail.com.
    • BMC Anesthesiol. 2015 Oct 15; 15: 147.

    BackgroundMaintaining the cuff pressure of endotracheal tubes (ETTs) within 20-30 cmH2O is a standard practice. The aim of the study was to evaluate the effectiveness of standard practice in maintaining cuff pressure within the target range.MethodsThis was a prospective observational study conducted in a tertiary-care intensive care unit, in which respiratory therapists (RTs) measured the cuff pressure 6 hourly by a handheld manometer. In this study, a research RT checked cuff pressure 2-4 h after the clinical RT measurement. Percentages of patients with cuff pressure levels above and below the target range were calculated. We identified predictors of low-cuff pressure.ResultsWe analyzed 2120 cuff-pressure measurements. The mean cuff pressure was 27 ± 2 cmH2O by the clinical RT and 21 ± 5 cmH2O by the research RT (p < 0.0001). The clinical RT documented that 98.0 % of cuff pressures were within the normal range. The research RT found the cuff pressures to be within the normal range in only 41.5 %, below the range in 53 % and above the range in 5.5 %. Low cuff pressure was found more common with lower ETT size (OR, 0.34 per 0.5 unit increase in ETT size; 95 % CI, 0.15-0.79) and with lower peak airway pressure (OR per one cm H2O increment, 0.93; 95 % CI, 0.87-0.99) on multivariate analysis.ConclusionsCuff pressure is frequently not maintained within the target range with low-cuff pressure being very common approximately 3 h after routine measurements. Low cuff pressure was associated with lower ETT size and lower peak airway pressure. There is a need to redesign the process for maintaining cuff pressure within the target range.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        

    hide…