    Point of Care INR testing devices: performance of the Roche CoaguChek XS and XS Plus in the UK NEQAS BC external quality assessment programme for healthcare professionals: four years' experience.

    • Dianne Patricia Kitchen, Steven Kitchen, Ian Jennings, Timothy A L Woods, David A Fitzmaurice, Ellen T Murray, and Isobel D Walker.
    • Point of Care, UK National External Quality Assessment Scheme for Blood Coagulation, Sheffield, UK. dianne.kitchen@coageqa.org.uk
    • J. Clin. Pathol. 2012 Dec 1; 65 (12): 1119-23.

    BackgroundVitamin K antagonists have been used for many decades and have been traditionally monitored by the measurement of the International Normalised Ratio (INR) in the laboratory. Introduction of Point of Care (POC) testing devices to measure INR has resulted in many tests being undertaken in primary care. External Quality Assessment (EQA) of these POC devices is recommended to ensure accuracy and reliability of INR results outside a laboratory setting.AimTo assess the quality of INR results for users of two POC devices (CoaguChek XS and CoaguChek XS Plus) over a four-year period.MethodsFour surveys (two samples) were sent in each 12-month period. The median INR value of each sample was calculated and the percentage deviation from this median determined. Any results greater than 15% from the median were considered to be outside consensus which indicated a possible problem within the testing system.ResultsVariability of INR results in this UK National External Quality Assessment Scheme (NEQAS) programme was comparable to that in the UK NEQAS EQA programme for laboratory INR testing. Occurrence of persistent problems was lower in the POC programme than the laboratory programme.ConclusionsUtilisation of an EQA programme for POC devices in primary care is feasible and necessary. Our data suggest for those health professionals using EQA, the reliability and accuracy of INR testing matches the quality of laboratory testing.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.