-
- James DuCanto, Yannick Lungwitz, Andreas Koch, Wataru Kähler, Laurie Gessell, Jack Simanonok, Norbert Roewer, Peter Kranke, and Bernd E Winkler.
- Department of Anesthesiology, Medical College of Wisconsin, Aurora St. Luke's Medical Center, Milwaukee, USA.
- Resuscitation. 2015 Aug 1; 93: 40-5.
IntroductionAirway management, mechanical ventilation and resuscitation can be performed almost everywhere--even in space--but not under water. The present study assessed the technical feasibility of resuscitation under water in a manikin model.MethodsTracheal intubation was assessed in a hyperbaric chamber filled with water at 20 m of depth using the Pentax AWS S100 video laryngoscope, the Fastrach™ intubating laryngeal mask and the Clarus optical stylet with guidance by a laryngeal mask airway (LMA) and without guidance. A closed suction system was used to remove water from the airways. A test lung was ventilated to a maximum depth of 50 m with a modified Oxylator(®) EMX resuscitator with its expiratory port connected either to a demand valve or a diving regulator. Automated chest compressions were performed to a maximum depth of 50 m using the air-driven LUCAS™ 1.ResultsThe mean cumulative time span for airway management until the activation of the ventilator was 36 s for the Fastrach™, 57 s for the Pentax AWS S100, 53s for the LMA-guided stylet and 43 s for the stylet without LMA guidance. Complete suctioning of the water from the airways was not possible with the suction system used. The Oxylator(®) connected to the demand valve ventilated at 50 m depth with a mean ventilation rate of 6.5 min(-1) vs. 14.7 min(-1) and minute volume of 4.5 l min(-1) vs. 7.6 l min(-1) compared to the surface. The rate of chest compression at 50 m was 228 min(-1) vs. 106 min(-1) compared to surface. The depth of compressions decreased with increasing depth.ConclusionAirway management under water appears to be feasible in this manikin model. The suction system requires further modification. Mechanical ventilation at depth is possible but modifications of the Oxylator(®) are required to stabilize ventilation rate and administered minute volumes. The LUCAS™ 1 cannot be recommended at major depth.Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.