    Comparison of noninvasive blood pressure measurements in patients with atrial fibrillation.

    • Zoe M Anastas, Elnora Jimerson, and Salomeja Garolis.
    • Providence Portland Medical Center, Portland, OR 97213, USA. zoe.anastas@providence.org
    • J Cardiovasc Nurs. 2008 Nov 1; 23 (6): 519-24; quiz 525-6.

    Background And Research ObjectiveLimited research is available on the accuracy of automatic blood pressure (BP) measurement devices in patients with irregular rhythms. The purpose of this study was to examine the agreement between different methods for noninvasive BP measurement in patients with atrial fibrillation.Subjects And MethodsIn a convenience sample of hospitalized patients with atrial fibrillation, a method-comparison study design was used to examine the agreement between 2 noninvasive devices for BP measurement (manual, automated). Blood pressure was obtained sequentially, with each device following manufacturer's directions and American Heart Association guidelines for BP determination and with BP order determined by random assignment. Heart rate and rhythm were determined from a continuous electrocardiographic monitoring. Heart rate was also recorded from the automated BP device. Differences and limits of agreement between the automated and reference standard (manual) BP devices were calculated and graphed according to the Bland-Altman method. Student t test was used to test differences in BP obtained with the 2 devices, as well as heart rate differences between the electrocardiographic monitor and automated BP device. The level of significance for all tests was set at 0.05.Results53 participants were observed. Bland-Altman analysis found a bias plus/minus precision of -0.91 +/- 11.4 mm Hg for systolic BP and 3.3 +/- 6.9 mm Hg for diastolic BP. A significant difference was found for the diastolic BP obtained with the automated device and with that of the manual device (t52 = 3.51, P = .0009) and for heart rate differences between the automated BP device and the cardiac monitor (t52 = 2.4, P = .0217).ConclusionThis study confirms that in the presence of irregular cardiac rhythms, diastolic BP and heart rate cannot reliably be measured with an automated BP device.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.