-
Am. Rev. Respir. Dis. · Jul 1989
Comparative StudyIn vitro versus in vivo comparison of endotracheal tube airflow resistance.
- P E Wright, J J Marini, and G R Bernard.
- Department of Medicine, Vanderbilt University, Nashville, Tennessee.
- Am. Rev. Respir. Dis. 1989 Jul 1; 140 (1): 10-6.
AbstractThe mechanics of gas flow in endotracheal (ET) tubes have been evaluated extensively in vitro under static and dynamic conditions. Previous bedside determinations of respiratory system mechanics in patients with acute respiratory failure have been based on assumptions derived from in vitro measurements without direct measurement of in vivo ET tube resistance (RET). We hypothesized that the RET measured in vivo would be greater than those values obtained in vitro when peak flow rates and ET tube size were held constant. We measured airflow, volume (pneumotachograph), esophageal pressure (nasogastric-esophageal balloon), and airway pressure (airway catheter) in 10 patients intubated with no. 8.0 orotracheal tubes. We also studied the static and dynamic flow-pressure relationships for five different sizes of ET tubes in vitro (artificial lung) (6.0, 7.0, 7.5, 8.0, and 8.5). The static and dynamic values of RET and the Rohrer coefficients of linear and nonlinear resistance (K1 and K2) were similar to values previously reported in the literature. Although there was considerable individual variation, values of RET measured in vivo were generally higher than those derived from in vitro measurements at both peak flow rates tested, perhaps because of secretions, head or neck position, tube deformation, or increased turbulence. We conclude that ET tubes contribute significantly to total airflow resistance and that RET is often significantly greater than indicated by in vitro studies. Estimates of work of breathing in critically ill patients must take into consideration the contribution of in vivo RET on total pulmonary system resistance.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.