- Johanna Wibault, Jacques Vaillant, Nicolas Vuillerme, Åsa Dedering, and Anneli Peolsson.
- Department of Medical and Health Sciences, Division of Physiotherapy, Faculty of Health Sciences, Linköping University, Linköping, Sweden. Johanna.Wibault@liu.se
- Man Ther. 2013 Oct 1; 18 (5): 403-9.
AbstractThis study had two purposes: to compare head repositioning accuracy (HRA) using the cervical range of motion (CROM) device between individuals with cervical radiculopathy caused by disc disease (CDD; n = 71) and neck- healthy individuals (n = 173); and to evaluate the test-retest reliability of the CROM device in individuals with CDD, and criterion validity between the CROM device and a laser in neck-healthy individuals, with quantification of measurement errors. Parameters of reliability and validity were expressed with intra- class- correlation coefficients (ICCs), and measurement errors with standard error of measurement (SEM) and Bland Altman limits of agreement. HRA (Mdn, IQR) differed significantly between individuals with CDD and neck- healthy individuals after rotation right 2.7° (6.0), 1.7° (2.7); and rotation left 2.7° (3.3), 1.3° (2.7) (p < = 0.021); 31% of individuals with CDD were classified as having impairment in HRA. The test-retest reliability of the CROM device in individuals with CDD showed ICCs of 0.79- 0.85, and SEMs of 1.4°- 2°. The criterion validity between the CROM device and the laser in neck-healthy individuals showed ICCs of 0.43- 0.91 and SEMs of 0.8°- 1.3°. The results support the use of the CROM device for quantifying HRA impairment in individuals with CDD in clinical practice; however, criterion validity between the CROM device and a laser in neck-healthy individuals was questionable. HRA impairment in individuals with CDD may be important to consider during rehabilitation and evaluated with the criterion established with the CROM device in neck-healthy individuals.Copyright © 2013 Elsevier Ltd. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.